Rapid and simultaneous detection of multiple pathogens in the lower reproductive tract during pregnancy based on loop-mediated isothermal amplification-microfluidic chip

Author:

Xu Xiaofang,Jia Yiguo,Li Ruolin,Wen Yuting,Liang Yuchen,Lao Guangjie,Liu Xiaojuan,Zhou Wei,Liu Huawei,Xie Jiang,Wang Xiaoxia,Xu Wenming,Sun Qun

Abstract

Abstract Background Female reproductive tract infection (RTI) is the common source of varied diseases, especially as an important risk factor for pregnancy outcomes, therefore the rapid, accurate and simultaneous detection of multiple pathogens is in urgent need for assisting the diagnosis and treatment of RTI in pregnant women. Streptococcus agalactiae (S. agalactiae), Enterococcus faecalis (E. faecalis), Gardnerella vaginalis (G. vaginalis), Candida albicans (C. albicans) and Chlamydia trachomatis (C. trachomatis) are five main pathogens in lower genital tract with high risk, serious consequences and clinical demands. The combination of loop-mediated isothermal amplification (LAMP) and microfluidic technology was used to develop the LAMP-microfluidic chip for rapid, simple, sensitive and simultaneous detection of the five target pathogens above. Results Standard strains and clinical isolates were used for the establishment of the novel LAMP method in tube and LAMP-microfluidic chip, followed by the chip detection on 103 clinical samples and PCR verification partially. The sensitivities of LAMP of S. agalactiae, E. faecalis, G. vaginalis, and C. albicans in tube were 22.0, 76.0, 13.2, 1.11 CFU/μL, respectively, and C. trachomatis was 41.3 copies/μL; on LAMP-microfluidic chip they were 260, 154, 3.9 and 7.53 CFU/μL, respectively, and C. trachomatis was 120 copies/μL. The positive coincidence rates of clinical stains in tube and on chip experiments were 100%. Compared with the classic culture method performed in hospitals, the positive coincidence rate of the 103 clinical samples detected by LAMP-microfluidic chip were 100%. For the six inconsistent ones, including four G. vaginalis and two C. albicans positive samples tested by LAMP-microfluidic chip and verified by PCR were negative by culturing method in hospitals, indicating the lack of efficient detection by the classic culturing method. Conclusion Our study suggested that the LAMP-microfluidic chips could simultaneously, efficiently, and accurately detect multiple main pathogens, including S. agalactiae, E. faecalis, G. vaginalis, C. albicans and C. trachomatis, in clinical samples of female RTI to give a great clinical value. Accordingly, this novel method has the potential to provide a valuable reference for female RTI screening and early diagnosis during pregnancy.

Funder

the National Key Research and Development Program

the International Research and Development Program of Sichuan

Publisher

Springer Science and Business Media LLC

Subject

Microbiology (medical),Microbiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3