Robotic-arm assisted medial unicondylar knee arthroplasty versus jig-based unicompartmental knee arthroplasty with navigation control: study protocol for a prospective randomised controlled trial

Author:

Kayani BabarORCID,Konan Sujith,Tahmassebi Jenni,Ayuob Atif,Moriarty Peter D.,Haddad Fares S.

Abstract

Abstract Background There remains a paucity of clinical studies assessing how any differences in accuracy of implant positioning between robotic-arm assisted unicompartmental knee arthroplasty (RO UKA) and conventional jig-based unicompartmental knee arthroplasty (CO UKA) translate to patient satisfaction, functional outcomes, and implant survivorship. The objectives of this study are to compare accuracy of implant positioning, limb alignment, patient satisfaction, functional outcomes, implant survivorship, cost-effectiveness, and complications in CO UKA versus RO UKA. Computer navigation will be used to assess intraoperative knee kinematics in all patients undergoing CO UKA. Methods and analysis This prospective randomised controlled trial will include 140 patients with symptomatic medial compartment knee arthritis undergoing primary UKA. Following informed consent, patients will be randomised to CO UKA (control group) or RO UKA (investigation group) at a ratio of 1:1 using an online random number generator. The primary objective of this study is to compare accuracy of implant positioning in CO UKA versus RO UKA. The secondary objectives are to compare the following outcomes between the two treatment groups: limb alignment, surgical efficiency, postoperative functional rehabilitation, functional outcomes, quality of life, range of motion, resource use, cost effectivness, and complications. Observers will review patients at regular intervals for 2 years after surgery to record predefined study outcomes pertaining to these objectives. Ethical approval was obtained from the London-Bloomsbury Research Ethics Committee, UK. The study is sponsored by University College London, UK. Discussion This study compares a comprehensive and robust range of clinical, functional, and radiological outcomes in CO UKA versus RO UKA. The findings of this study will provide an improved understanding of the differences in CO UKA versus RO UKA with respect to accuracy of implant positioning, patient satisfaction, functional outcomes, implant survivorship, cost-effectiveness, and complications. Trial registration ClinicalTrials.gov NCT04095637. Registered on 19 September 2019.

Funder

Stryker

Publisher

Springer Science and Business Media LLC

Subject

Pharmacology (medical),Medicine (miscellaneous)

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3