Author:
Buhre Wolfgang,de Korte-de Boer Dianne,de Abreu Marcelo Gama,Scheeren Thomas,Gruenewald Matthias,Hoeft Andreas,Spahn Donat R.,Zarbock Alexander,Daamen Sylvia,Westphal Martin,Brauer Ute,Dehnhardt Tamara,Schmier Sonja,Baron Jean-Francois,De Hert Stefan,Gavranović Željka,Cholley Bernard,Vymazal Tomas,Szczeklik Wojciech,Bornemann-Cimenti Helmar,Soro Domingo Marina Blanca,Grintescu Ioana,Jankovic Radmilo,Belda Javier
Abstract
Abstract
Background
Hydroxyethyl starch (HES) solutions are used for volume therapy to treat hypovolemia due to acute blood loss and to maintain hemodynamic stability. This study was requested by the European Medicines Agency (EMA) to provide more evidence on the long-term safety and efficacy of HES solutions in the perioperative setting.
Methods
PHOENICS is a randomized, controlled, double-blind, multi-center, multinational phase IV (IIIb) study with two parallel groups to investigate non-inferiority regarding the safety of a 6% HES 130 solution (Volulyte 6%, Fresenius Kabi, Germany) compared with a crystalloid solution (Ionolyte, Fresenius Kabi, Germany) for infusion in patients with acute blood loss during elective abdominal surgery. A total of 2280 eligible patients (male and female patients willing to participate, with expected blood loss ≥ 500 ml, aged > 40 and ≤ 85 years, and ASA Physical status II–III) are randomly assigned to receive either HES or crystalloid solution for the treatment of hypovolemia due to surgery-induced acute blood loss in hospitals in up to 11 European countries. The dosing of investigational products (IP) is individualized to patients’ volume needs and guided by a volume algorithm. Patients are treated with IP for maximally 24 h or until the maximum daily dose of 30 ml/kg body weight is reached.
The primary endpoint is the treatment group mean difference in the change from the pre-operative baseline value in cystatin-C-based estimated glomerular filtration rate (eGFR), to the eGFR value calculated from the highest cystatin-C level measured during post-operative days 1-3. Further safety and efficacy parameters include, e.g., combined mortality/major post-operative complications until day 90, renal function, coagulation, inflammation, hemodynamic variables, hospital length of stay, major post-operative complications, and 28-day, 90-day, and 1-year mortality.
Discussion
The study will provide important information on the long-term safety and efficacy of HES 130/0.4 when administered according to the approved European product information. The results will be relevant for volume therapy of surgical patients.
Trial registration
EudraCT 2016-002162-30. ClinicalTrials.govNCT03278548
Publisher
Springer Science and Business Media LLC
Subject
Pharmacology (medical),Medicine (miscellaneous)
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献