Author:
Savvoulidis Panagiotis,Nadir M. Adnan,Moody William E.,Steeds Richard,Ludman Peter F.,Bradley Joseph R.,Singh Aldrin,Lawton Ewa,Doshi Sagar N.
Abstract
Abstract
Background
Routine pre-discharge echocardiography (ECHO) is recommended post transcatheter aortic valve implantation (TAVI) as a baseline for future comparison. However, there is no clear guidance on the optimal timing of this study.
Aim
The purpose of this retrospective study was to investigate the safety and work-force efficiency of intraprocedural same-day ECHO versus next-day ECHO, following transfemoral TAVI.
Methods and results
In this retrospective study 100 consecutive patients who underwent intraprocedural ECHO only were compared with 100 consecutive patients undergoing both intraprocedural and routine next-day ECHO following elective transfemoral TAVI. All patients received the Sapien 3/Ultra transcatheter heart valve and were treated with a minimalist procedure with conscious sedation. The composite of in-hospital mortality, urgent ECHO and new tamponade after leaving the cath lab and before discharge was not different between the two groups (4 vs. 4%, P = 1). There was no paravalvular leak more than mild in any of the cases. Length of stay was similar (1 day).
Conclusions
Intraprocedural post-TAVI ECHO appears as safe as next day pre-discharge ECHO and obviates the need for a routine next day study, thereby reducing burden on echocardiography services and allows better utilisation of resources.
Publisher
Springer Science and Business Media LLC
Subject
Advanced and Specialized Nursing,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology