Author:
Brix Gunnar,Günther Elisabeth,Rössler Ute,Endesfelder David,Kamp Alexandra,Beer Ambros,Eiber Matthias
Abstract
Abstract
Background
Given the increasing clinical use of PET/MRI, potential risks to patients from simultaneous exposure to ionising radiation and (electro)magnetic fields should be thoroughly investigated as a precaution. With this aim, the genotoxic potential of 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) and a strong static magnetic field (SMF) were evaluated both in isolation and in combination using the γH2AX assay detecting double-strand breaks in lymphocyte DNA.
Methods
Thirty-two healthy young volunteers allocated to three study arms were exposed to [18F]FDG alone, to a 3-T SMF alone or to both combined over 60 min at a PET/CT or a PET/MRI system. Blood samples taken after in vivo exposure were incubated up to 60 min to extend the irradiation of blood by residual [18F]FDG within the samples and the time to monitor the γH2AX response. Absorbed doses to lymphocytes delivered in vivo and in vitro were estimated individually for each volunteer exposed to [18F]FDG. γH2AX foci were scored automatically by immunofluorescence microscopy.
Results
Absorbed doses to lymphocytes exposed over 60 to 120 min to [18F]FDG varied between 1.5 and 3.3 mGy. In this time interval, the radiotracer caused a significant median relative increase of 28% in the rate of lymphocytes with at least one γH2AX focus relative to the background rate (p = 0.01), but not the SMF alone (p = 0.47). Simultaneous application of both agents did not result in a significant synergistic or antagonistic outcome (p = 0.91).
Conclusion
There is no evidence of a synergism between [18F]FDG and the SMF that may be of relevance for risk assessment of PET/MRI.
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献