Head to head comparison of [99mTc]Tc(CO)3(NTA) and [99mTc]Tc-MAG3 in patients with suspected obstruction

Author:

Taylor Andrew T.ORCID,Lipowska Malgorzata,Halkar Raghuveer K.

Abstract

Abstract Purpose 99mTc-tricarbonyl-nitrilotriacetic acid, [99mTc]Tc(CO)3(NTA), is a new 99mTc-renal radiopharmaceutical with a clearance equal to that of 131I-ortho-iodohippuran, [131I]I-OIH. Our purpose was to compare the performance of [99mTc]Tc(CO)3(NTA) and [99mTc]Tc-MAG3 in patients with suspected obstruction. Methods [99mTc]Tc(CO)3(NTA) was prepared with commercially available NTA ligand and CRS Isolink kit, and isolated by HPLC. Eighteen adult patients referred for diuretic renography received an intravenous injection of approximately 40 mg of furosemide 15 min prior to either [99mTc]Tc(CO)3(NTA) or [99mTc]Tc-MAG3 (mean activity of 47 ± 4.4 MBq). Data were acquired for 24 min followed by an anterior image of the liver and gall bladder and a measure of voided volume. Patients received a second furosemide injection equal to one third of the original dose followed fifteen minutes later by administration of the alternate tracer, mean activity of 320 ± 34 MBq. Clearances were measured using a camera-based technique. Results The clearance of NTA was greater than that of MAG3, 331 ± 146 versus 271 ± 105 mL/min/1.73 m2, respectively, p < 0.0001. The kidney to background ratio for NTA was greater than that of MAG3 for both left and right kidneys, p < 0.001; the 20 min/maximum count ratio was significantly less, p < 0.0001. There was no significant difference in the voiding volumes following NTA and MAG3 administration, 598 ± 237 mL versus 498 ± 170 mL, respectively, p = 0.07. Gall bladder activity was not observed with NTA but was present in 6/17 MAG3 studies. Images and renogram curves were comparable except for two patients where the NTA study excluded obstruction but the MAG3 study suggested an indeterminate or obstructed kidney. Conclusions Unlike MAG3, NTA is not eliminated via the hepatobiliary track. Moreover, NTA has a higher kidney to background ratio and more rapid clearance than MAG3. These advantages should allow more robust camera-based clearance measurements and may lead to better discrimination between obstructed and non-obstructed kidneys.

Funder

National Institute of Diabetes and Digestive and Kidney Diseases

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3