Development of a minimally invasive simultaneous estimation method for quantifying translocator protein binding with [18F]FEPPA positron emission tomography

Author:

Dassanayake PraveenORCID,Anazodo Udunna C.,Liu Linshan,Narciso Lucas,Iacobelli Maryssa,Hicks Justin,Rusjan Pablo,Finger Elizabeth,St Lawrence Keith

Abstract

Abstract Background The purpose of this study was to assess the feasibility of using a minimally invasive simultaneous estimation method (SIME) to quantify the binding of the 18-kDa translocator protein tracer [18F]FEPPA. Arterial sampling was avoided by extracting an image-derived input function (IDIF) that was metabolite-corrected using venous blood samples. The possibility of reducing scan duration to 90 min from the recommended 2–3 h was investigated by assuming a uniform non-displaceable distribution volume (VND) to simplify the SIME fitting. Results SIME was applied to retrospective data from healthy volunteers and was comprised of both high-affinity binders (HABs) and mixed-affinity binders (MABs). Estimates of global VND and regional total distribution volume (VT) from SIME were not significantly different from values obtained using a two-tissue compartment model (2CTM). Regional VT estimates were greater for HABs compared to MABs for both the 2TCM and SIME, while the SIME estimates had lower inter-subject variability (41 ± 17% reduction). Binding potential (BPND) values calculated from regional VT and brain-wide VND estimates were also greater for HABs, and reducing the scan time from 120 to 90 min had no significant effect on BPND. The feasibility of using venous metabolite correction was evaluated in a large animal model involving a simultaneous collection of arterial and venous samples. Strong linear correlations were found between venous and arterial measurements of the blood-to-plasma ratio and the remaining [18F]FEPPA fraction. Lastly, estimates of BPND and the specific distribution volume (i.e., VS = VT − VND) from a separate group of healthy volunteers (90 min scan time, venous-scaled IDIFs) agreed with estimates from the retrospective data for both genotypes. Conclusions The results of this study demonstrate that accurate estimates of regional VT, BPND and VS can be obtained by applying SIME to [18F]FEPPA data. Furthermore, the application of SIME enabled the scan time to be reduced to 90 min, and the approach worked well with IDIFs that were scaled and metabolite-corrected using venous blood samples.

Funder

Alzheimer Society

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3