Standardized image quality for 68Ga-DOTA-TATE PET/CT

Author:

Cox Christina P. W.,Segbers Marcel,Graven Laura H.,Brabander Tessa,van Assema Daniëlle M. E.

Abstract

Abstract Background Positron emission tomography (PET) imaging with 68Gallium labeled somatostatin analogues (68Ga-DOTA-SSA) plays a key role in neuroendocrine tumor management. The impact of patient size on PET image quality is not well known for PET imaging with 68Ga-DOTA-SSA. The aim of this study is to propose a dose regimen based on patient size that optimizes image quality and yields sufficient image quality for diagnosis. Methods Twenty-one patients (12 males, 9 females) were prospectively included for 68Gallium-DOTA-Tyr3-Octreotate (68Ga-DOTA-TATE) PET/CT, which was acquired in whole body list mode using 6 min per bed position (mbp). The list-mode events were randomly sampled to obtain 1 to 6 mbp PET reconstructions. For semi-quantitative assessment of image quality, the signal-to-noise ratio (SNR) was measured in the liver. The SNR normalized (SNRnorm) for administered activity and mbp was correlated with body mass, length, body mass index, body mass/length, and lean body mass. Three experienced nuclear medicine physicians visually graded image quality using a 4-point scale, and categorically scored the number of somatostatin-receptor positive lesions for each reconstruction. To investigate the impact of image quality on lesion quantification, the mean, maximum, and peak standardized uptake values (SUVs) of one abdominal lesion were measured in the 1 to 6 mbp PET reconstructions. Results Of all patient-dependent parameters, body mass showed the strongest correlation (R2 = 0.6) with SNRnorm. Lesion detectability analysis showed no significant difference for 3-5 mbp compared with the complete 6 mbp PET reconstruction. The SUV measurements showed no significant (p > 0.05) differences across the reconstructions. Visual assessment revealed that an SNR of 6.2 results in PET scans with moderate to good image quality. A non-linear expression was derived to calculate the required (dose × acquisition time) product (DTP) for the chosen SNR level of 6.2 that would yield a more constant image quality. Conclusion Body mass can be used to predict 68Ga-DOTA-TATE PET image quality. The proposed non-linear dose regimen based on body mass standardizes the image quality while maintaining sufficient image quality for diagnosis.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3