Abstract
Abstract
Background
The Centiloid scale was developed to standardise the results of beta-amyloid (Aβ) PET. We aimed to determine the Centiloid unit (CL) thresholds for CERAD sparse and moderate-density neuritic plaques, Alzheimer’s disease neuropathologic change (ADNC) score of intermediate or high probability of Alzheimer’s Disease (AD), final clinicopathological diagnosis of AD, and expert visual read of a positive Aβ PET scan.
Methods
Aβ PET results in CL for 49 subjects were compared with post-mortem findings, visual read, and final clinicopathological diagnosis. The Youden Index was used to determine the optimal CL thresholds from receiver operator characteristic (ROC) curves.
Results
A threshold of 20.1 CL (21.3 CL when corrected for time to death, AUC 0.97) yielded highest accuracy in detecting moderate or frequent plaque density while < 10 CL was optimal for excluding neuritic plaque. The threshold for ADNC intermediate or high likelihood AD was 49.4 CL (AUC 0.98). Those cases with a final clinicopathological diagnosis of AD yielded a median CL result of 87.7 (IQR ± 42.2) with 94% > 45 CL. Positive visual read agreed highly with results > 26 CL.
Conclusions
Centiloid values < 10 accurately reflected the absence of any neuritic plaque and > 20 CL indicated the presence of at least moderate plaque density, but approximately 50 CL or more best confirmed both neuropathological and clinicopathological diagnosis of Alzheimer’s disease.
Publisher
Springer Science and Business Media LLC
Subject
Cognitive Neuroscience,Neurology (clinical),Neurology
Cited by
98 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献