Abstract
Abstract
Background
The L test is a modified version of the timed up and go test (TUG) with an L-shaped walking path. The L test is more extensive than other performance tests, especially in turn direction and specific tasks. The study aimed to evaluate the test-retest reliability, concurrent validity, and minimal detectable change of the L test in patients with total hip arthroplasty (THA). A cross-sectional study was conducted with 33 unilateral and primary THA patients. The L test was performed twice with an interval of an hour on the same day for the test-retest reliability. Timed up and go test (TUG), five times sit to stand test (FTST), and Harris hip score (HHS) were carried out for the analysis of the concurrent validity of the L test.
Results
The mean age of the participants was 74.6 ± 10.3 years. The ICC score of the L test was 0.992. Test-retest reliability was excellent. SEM95 and MDC95 values were 3.39 and 9.39, respectively. Both TUG and HHS were strongly correlated with the L test (r1 = 0.889, r2 = −0.568, p < 0.001). However, there was no significant correlation between FTST and L test (r = 0.024, p > 0.05).
Conclusions
The L test is valid and reliable performance measurement in patients with primary unilateral THA. MDC95 of the L test is an essential reference for clinicians in the rehabilitation follow-up process of THA patients.
Publisher
Springer Science and Business Media LLC
Subject
General Medicine,Genetics,Animal Science and Zoology
Reference26 articles.
1. Heiberg KE, Bruun-Olsen V, Ekeland A, Mengshoel AM. Effect of a walking skill training program in patients who have undergone total hip arthroplasty: followup one year after surgery. Arthritis Care Res. 2012;64(3):415–23. https://doi.org/10.1002/acr.20681.
2. Gogia PP, Christensen CM, Schmidt C. Total hip replacement in patients with osteoarthritis of the hip: improvement in pain and functional status. Orthopedics. 1994;17(2):145–50. https://doi.org/10.3928/0147-7447-19940201-10.
3. van den Akker-Scheek I, Stevens M, Bulstra SK, Groothoff JW, van Horn JR, Zijlstra W. Recovery of gait after short-stay total hip arthroplasty. Arch Phys Med Rehabil. 2007;88(3):361–7. https://doi.org/10.1016/j.apmr.2006.11.026.
4. Unver B, Kahraman T, Kalkan S, Yuksel E, Karatosun V, Gunal I. Test-retest reliability of the 50-foot timed walk and 30-second chair stand test in patients with total hip arthroplasty. Acta Orthop Belg. 2015;81(3):435–41.
5. Nicolini-Panisson RDA, Donadio MVF. Timed “Up & Go” test in children and adolescents. Rev Paulista Pediatr. 2013;31(3):377–83.