Author:
Deng Jing,Cao Yuwei,Lu Yao,Song Jiacheng,Zhang Aining,Zhao Meng,Zhou Xin,Mu Xihu,Qu Feifei,Wu Feiyun,Chen Ting
Abstract
Abstract
Objective
It is critical to early monitor and manage small-for-gestational age (SGA) infants with truly adverse outcomes not detected by conventional methods. We aimed to explore the value of diffusion-weighted imaging (DWI)-based virtual magnetic resonance elastography (vMRE) and intravoxel incoherent motion (IVIM)-based biexponential and stretched exponential parameters in predicting adverse outcomes of SGA infants.
Methods
Twenty SGA infants with adverse outcomes and forty without adverse outcomes were included in this prospective study. One DWI-based vMRE parameter [the stiffness value (μdiff)], five IVIM–based parameters [true diffusion coefficient (D), pseudo-diffusion coefficient (D*), perfusion fraction (f), diffusion distribution coefficient (DDC), and diffusion heterogeneity index (Alpha)] and apparent diffusion coefficient (ADC) were calculated and compared between groups. The predictive efficiency was compared by the logistic regression analysis and receiver operating characteristic curve analysis. The relationship between the μdiff value with gestational age was also evaluated.
Results
The placental μdiff value was remarkably higher, and the f, DDC, and ADC values were considerably lower in the SGA infants with adverse outcomes compared with those without adverse outcomes. The μdiff and f value were predictive risk factors for SGA infants with adverse outcomes. A combined predictive model (μdiff and f) improved the predictive efficacy. Moreover, there was no statistically significant correlation between the placental stiffness value and gestational age.
Conclusions
Functional MRI parameters to quantify placenta elastography and microcirculation in SGA patients. This might be a useful tool to assess placental function and a vital non-invasive supplement for predicting adverse outcomes of SGA infants.
Critical relevance statement
This prospective study shows DWI-based virtual magnetic resonance elastography and intravoxel incoherent motion-based functional parameters to quantify placenta elastography and microcirculation in small-for-gestational-age patients, which could complement existing non-invasive methods for monitoring and predicting neonatal perinatal adverse outcome.
Key points
• vMRE is an emerging non-invasive imaging technique for evaluating placenta stiffness.
• SGA infants with adverse outcome have stiffer placental elasticity and lower microcirculation.
• Risk factors combination displayed better efficacy in predicting adverse outcomes of SGA.
Graphical Abstract
Funder
Young Scholars Fostering Fund of the First Affiliated Hospital of Nanjing Medical University
National key research and development program
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献