Dosimetric quantities and effective dose in medical imaging: a summary for medical doctors

Author:

Vano Eliseo,Frija Guy,Loose Reinhard,Paulo Graciano,Efstathopoulos Efstathios,Granata Claudio,Andersson Jonas,

Abstract

AbstractThis review presents basic information on the dosimetric quantities used in medical imaging for reporting patient doses and establishing diagnostic reference levels. The proper use of the radiation protection quantity “effective dose” to compare doses delivered by different radiological procedures and different imaging modalities with its uncertainties and limitations, is summarised. The estimates of population doses required by the European Directive on Basic Safety Standards is commented on. Referrers and radiologists should be familiar with the dose quantities to inform patients about radiation risks and benefits. The application of effective dose on the cumulative doses from recurrent imaging procedures is also discussed. Patient summary: Basic information on the measurement units (dosimetric quantities) used in medical imaging for reporting radiation doses should be understandable to patients. The Working Group on “Dosimetry for imaging in clinical practice” recommended that a brief explanation on the used dosimetric quantities and units included in the examination imaging report, should be available for patients. The use of the quantity “effective dose” to compare doses to which patients are exposed to from different radiological procedures and its uncertainties and limitations, should also be explained in plain language. This is also relevant for the dialog on to the cumulative doses from recurrent imaging procedures. The paper summarises these concepts, including the need to estimate the population doses required by the European Directive on Basic Safety Standards. Referrers and radiologists should be familiar with the dose quantities to inform patients about radiation risks and benefits.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

Reference30 articles.

1. European Council (2014) Council Directive 2013/59/Euratom of 5 December 2013, laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation. Off J Eur Union L 13:73

2. Valentin J, International Commission on Radiation Protection (2007) Managing patient dose in multi-detector computed tomography (MDCT). ICRP Publication 102. Ann ICRP 37(1):1–79

3. AAPM. Size-specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations. AAPM Report No. 204 (2011). American Association of Physicists in Medicine, College Park, MD

4. Vañó E, Miller DL, Martin CJ et al (2017) ICRP Publication 135: diagnostic reference levels in medical imaging. Ann ICRP 46(1):1–144. https://doi.org/10.1177/0146645317717209

5. (2007) The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP 37(2–4):1–332