Radiation reduction for interventional radiology imaging: a video frame interpolation solution

Author:

Tang Zhijiang,Xiong Qiang,Wu Xuantai,Xu Tianyi,Shi Yuxuan,Xu Ximing,Xu Jun,Wang RuijueORCID

Abstract

Abstract Purpose The aim of this study was to diminish radiation exposure in interventional radiology (IR) imaging while maintaining image quality. This was achieved by decreasing the acquisition frame rate and employing a deep neural network to interpolate the reduced frames. Methods This retrospective study involved the analysis of 1634 IR sequences from 167 pediatric patients (March 2014 to January 2022). The dataset underwent a random split into training and validation subsets (at a 9:1 ratio) for model training and evaluation. Our approach proficiently synthesized absent frames in simulated low-frame-rate sequences by excluding intermediate frames from the validation subset. Accuracy assessments encompassed both objective experiments and subjective evaluations conducted by nine radiologists. Results The deep learning model adeptly interpolated the eliminated frames within IR sequences, demonstrating encouraging peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) results. The average PSNR values for angiographic, subtraction, and fluoroscopic modes were 44.94 dB, 34.84 dB, and 33.82 dB, respectively, while the corresponding SSIM values were 0.9840, 0.9194, and 0.7752. Subjective experiments conducted with experienced interventional radiologists revealed minimal discernible differences between interpolated and authentic sequences. Conclusion Our method, which interpolates low-frame-rate IR sequences, has shown the capability to produce high-quality IR images. Additionally, the model exhibits potential for reducing the frame rate during IR image acquisition, consequently mitigating radiation exposure. Critical relevance statement This study presents a critical advancement in clinical radiology by demonstrating the effectiveness of a deep neural network in reducing radiation exposure during pediatric interventional radiology while maintaining image quality, offering a potential solution to enhance patient safety. Key points • Reducing radiation: cutting IR image to reduce radiation. • Accurate frame interpolation: our model effectively interpolates missing frames. • High visual quality in terms of PSNR and SSIM, making IR procedures safer without sacrificing quality. Graphical Abstract

Funder

National Natural Science Foundation of China

Children’s Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3