Can imaging be the new yardstick for diagnosing peripheral neuropathy?—a comparison between high resolution ultrasound and MR neurography with an approach to diagnosis

Author:

Agarwal AakankshaORCID,Chandra Abhishek,Jaipal Usha,Bagarhatta Meenu,Mendiratta Kuldeep,Goyal Alka,Kumar Raghav,Mangalhara Naresh

Abstract

Abstract Purpose Peripheral neuropathies are a group of disorders which affect the peripheral nervous system which have been conventionally diagnosed using electrodiagnostic studies. This study was carried out to assess the role of imaging in diagnosing peripheral mononeuropathy as exact anatomical localisation of the pathology is possible using high-resolution ultrasound and MR neurography, the modalities assessed in this study. Method A hospital-based prospective analytical study was carried out in a resource-limited setting on 180 peripheral nerves in 131 patients with symptoms of peripheral mononeuropathy after taking IRB approval. Each patient underwent high-resolution ultrasound examination and MR neurography, findings of which were then compared and statistically analysed assuming electrodiagnostic findings as the gold standard. Results Overall, the diagnostic accuracy was highest for the proton density fat-saturated MR sequence (93.89%) followed by high-resolution ultrasound (80%). The sensitivity was highest for proton density fat-saturated sequence while the T1 MR sequence had the highest specificity. Combined diagnostic accuracy of both modalities was calculated to be 93.33% with a negative predictive value of 80%. High-resolution ultrasound and MRI equally detected the cases with nerve discontinuity, while neuromas were better identified on MRI. Conclusion With the advent of higher frequency probes and improved MR field strength, imaging of peripheral nerves is possible with better accuracy. Imaging assessment of nerves allows anatomical delineation with identification of exact site of involvement. This comparative study demonstrates the role of imaging in diagnosing peripheral nerve pathologies with the accuracy of MRI as high as 93.89% which may serve as an imaging gold standard. High-resolution ultrasound, being quicker, cost effective and a comparable accuracy of 80% can serve as a reliable screening tool. This study incorporates a larger study group and compares HRUS with MRI, taking NCV as gold standard, which has not been done in the preceding studies. With this study, we conclude that these two imaging modalities are not mutually exclusive. Rather, they complement each other and can be used in conjunction as an imaging yardstick for diagnosing peripheral neuropathies.

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3