Percutaneous Native Renal Biopsy Adequacy: A Successful Interdepartmental Quality Improvement Activity

Author:

Geldenhuys Laurette1,Nicholson Peter1,Sinha Namita1,Dini Angela1,Doucette Steve2,Alfaadhel Talal3,Keough Valerie4,West Michael3

Affiliation:

1. Department of Pathology and Laboratory Medicine, Dalhousie University, Halifax, Nova Scotia, Canada

2. Department of Community Health and Epidemiology, Dalhousie University, Halifax, Nova Scotia, Canada

3. Department of Medicine, Dalhousie University, Halifax, Nova Scotia, Canada

4. Department of Diagnostic Imaging, Dalhousie University, Halifax, Nova Scotia, Canada

Abstract

Background: An adequate renal biopsy is essential for diagnosis and treatment of medical renal disease. Objective: We evaluated two initiatives to improve adequacy of renal biopsy samples at our centre. Design: Retrospective determination of renal biopsy adequacy. Setting: Queen Elizabeth II Health Sciences Centre. Patients: Patients undergoing medical renal biopsies. Measurements: Renal biopsy adequacy. Methods: The first initiative was to restrict the performance of biopsies to a smaller group of radiologists and to include a comment on biopsy adequacy in every pathology report. The second initiative was to introduce on-site adequacy assessment by a medical laboratory technologist. Native renal and allograft biopsy adequacies were calculated for three periods: 1) baseline, October 2005 to September 2006; 2) after implementation of the first initiative, January 2007 to September 2011; and 3) after implementation of the second initiative, October 2011 to September 2012. A subset of native renal biopsies was examined to determine if there was a relationship between adequacy and number of passes. Results: The percentages of adequate native renal biopsies during the first, second, and third periods were 31%, 72% and 90%, respectively. This represents a significant increase (40%, p < 0.0001) in adequacy following the first initiative, and another significant increase (18%, p = 0.0003) following the second initiative. The percentages of adequate renal allograft biopsies during the first, second, and third periods were 75%, 56% and 69%, respectively. These changes in adequacy were not statistically significant. In the subset of native renal biopsies examined, a biopsy comprising more than three cores was not associated with increase in adequacy. Limitations: The most important limitation is the lack of generally accepted and applied adequacy criteria limiting generalizability of our findings. Conclusions: Restricting the performance of biopsies to subspecialist operators, including an adequacy statement in the renal biopsy report and on-site adequacy assessment were effective in significantly improving native renal biopsy adequacy. This improvement appeared unrelated to an increase in the number of passes taken with a biopsy needle. Neither initiative improved the low adequacy of allograft biopsies.

Publisher

SAGE Publications

Subject

Nephrology

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3