Examination of fully automated mammographic density measures using LIBRA and breast cancer risk in a cohort of 21,000 non-Hispanic white women
-
Published:2023-08-06
Issue:1
Volume:25
Page:
-
ISSN:1465-542X
-
Container-title:Breast Cancer Research
-
language:en
-
Short-container-title:Breast Cancer Res
Author:
Habel Laurel A.,Alexeeff Stacey E.,Achacoso Ninah,Arasu Vignesh A.,Gastounioti Aimilia,Gerstley Lawrence,Klein Robert J.,Liang Rhea Y.,Lipson Jafi A.,Mankowski Walter,Margolies Laurie R.,Rothstein Joseph H.,Rubin Daniel L.,Shen Li,Sistig Adriana,Song Xiaoyu,Villaseñor Marvella A.,Westley Mark,Whittemore Alice S.,Yaffe Martin J.,Wang Pei,Kontos Despina,Sieh Weiva
Abstract
Abstract
Background
Breast density is strongly associated with breast cancer risk. Fully automated quantitative density assessment methods have recently been developed that could facilitate large-scale studies, although data on associations with long-term breast cancer risk are limited. We examined LIBRA assessments and breast cancer risk and compared results to prior assessments using Cumulus, an established computer-assisted method requiring manual thresholding.
Methods
We conducted a cohort study among 21,150 non-Hispanic white female participants of the Research Program in Genes, Environment and Health of Kaiser Permanente Northern California who were 40–74 years at enrollment, followed for up to 10 years, and had archived processed screening mammograms acquired on Hologic or General Electric full-field digital mammography (FFDM) machines and prior Cumulus density assessments available for analysis. Dense area (DA), non-dense area (NDA), and percent density (PD) were assessed using LIBRA software. Cox regression was used to estimate hazard ratios (HRs) for breast cancer associated with DA, NDA and PD modeled continuously in standard deviation (SD) increments, adjusting for age, mammogram year, body mass index, parity, first-degree family history of breast cancer, and menopausal hormone use. We also examined differences by machine type and breast view.
Results
The adjusted HRs for breast cancer associated with each SD increment of DA, NDA and PD were 1.36 (95% confidence interval, 1.18–1.57), 0.85 (0.77–0.93) and 1.44 (1.26–1.66) for LIBRA and 1.44 (1.33–1.55), 0.81 (0.74–0.89) and 1.54 (1.34–1.77) for Cumulus, respectively. LIBRA results were generally similar by machine type and breast view, although associations were strongest for Hologic machines and mediolateral oblique views. Results were also similar during the first 2 years, 2–5 years and 5–10 years after the baseline mammogram.
Conclusion
Associations with breast cancer risk were generally similar for LIBRA and Cumulus density measures and were sustained for up to 10 years. These findings support the suitability of fully automated LIBRA assessments on processed FFDM images for large-scale research on breast density and cancer risk.
Funder
National Institutes of Health
Publisher
Springer Science and Business Media LLC
Reference22 articles.
1. Boyd NF, Rommens JM, Vogt K, Lee V, Hopper JL, Yaffe MJ, Paterson AD. Mammographic breast density as an intermediate phenotype for breast cancer. Lancet Oncol. 2005;6(10):798–808. 2. McCormack VA, dos Santos SI. Breast density and parenchymal patterns as markers of breast cancer risk: a meta-analysis. Cancer Epidemiol Biomark Prev. 2006;15(6):1159–69. 3. Sickles EA, D'Orsi CJ, Bassett LW, Appleton CM, Berg WA, Burnside ES, Feig SA, Gavenonis SC, Newell MS, Trinh MM. ACR BI-RADS mammography. In: vACR BI-RADS atlas, breast imaging reporting and data system. Reston, VA: American College of Radiology; 2013. 4. Byrne C, Schairer C, Wolfe J, Parekh N, Salane M, Brinton LA, Hoover R, Haile R. Mammographic features and breast cancer risk: effects with time, age, and menopause status. J Natl Cancer Inst. 1995;87(21):1622–9. 5. Lee-Han H, Cooke G, Boyd NF. Quantitative evaluation of mammographic densities: a comparison of methods of assessment. Eur J Cancer Prev. 1995;4(4):285–92.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|