Author:
Nishimura Jun,Dharap Parag,Raimbault Sebastien
Abstract
Abstract
Background
Hematology analyzers display abnormal parameters during malaria infection providing insightful information for suspecting and assessing malaria infection. The goal of this study is to demonstrate the potential of a three-part differential hematology analyzer to assess malaria, provide information about the parasitemia, and discuss the importance of combining C-reactive protein (CRP) with hematology parameters to obtain further information about the malaria infection.
Methods
The present study shows the results of a case–control study during the monsoon season of years 2018 and 2019 in Mumbai, India. The study considers 1008 non-malaria febrile cases, 209 P. vivax and 31 P. falciparum positive malaria samples, five cases of mixed P. vivax and P. falciparum infection, and three co-infection cases of P. vivax and dengue. Raw data from the three-part analyzer LC-667G CRP (HORIBA) and the corresponding microscopic findings (golden standard for diagnosis of malaria) were obtained for each sample.
Results
The medians of platelet counts (PLT) were 102.5, 109.0, and 223.0 × 103/µL, while CRP medians were 67.4, 81.4 and 10.4 mg/L in P. vivax, P. falciparum and control groups respectively (p < 0.001 in Mann–Whitney U tests between malaria and control groups). Compared with negative samples, platelets counting less than 161.5 × 103/µL were observed on malaria patients (OR 19.12, 95% CI 11.89–30.75). Especially in P. vivax cases, an abnormal peak was frequently observed in the white blood cells (WBC) histogram around the 37fL channel. The events counted around that channel showed a linear correlation with the counting of red blood cells infected predominantly with larger parasitic forms. Parameters like CRP (rs = 0.325, p < 0.001), WBC (rs = 0.285, p < 0.001) and PLT (rs = − 0.303, p < 0.001) were correlated with the parasitemia of P. vivax samples. Between the malaria and dengue groups, the highest area under the receiver operating characteristic curve was observed on CRP (0.867, CRP ≥ 26.85 mg/L).
Conclusions
A three-part differential hematology analyzer has the potential to not only trigger malaria diagnosis confirmation but also assess the severity of the infection when CRP is considered.
Publisher
Springer Science and Business Media LLC
Reference36 articles.
1. WHO. World malaria report 2018. Geneva: World Health Organization; 2018. http://www.who.int/malaria/publications/world-malaria-report-2018/en/. Accessed 20 Jan 2020.
2. McMorrow ML, Aidoo M, Kachur SP. Malaria rapid diagnostic tests in elimination settings—can they find the last parasite? Clin Microbiol Inf. 2011;17:1624–31.
3. Campuzano-Zuluaga G, Hänscheid T, Grobusch MP. Automated haematology analysis to diagnose malaria. Malar J. 2010;9:346.
4. Mendelow BV, Lyons C, Nhlangothi P, Tana M, Munster M, Wypkema E, Liebowitz L, Marshall L, Scott S, Coetzer TL. Automated malaria detection by depolarization of laser light. Br J Haematol. 1999;104(3):499–503.
5. Jain M, Gupta S, Jain J, Grover RK. Usefulness of automated cell counter in detection of malaria in a cancer set up-Our experience. Indian J Pathol Microbiol. 2012;55:467–73.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献