Comparative performance of contact plate metod and swab method for surface microbial contamination on medical fabrics

Author:

Chen Feng,Li Yaru,Wang Wanqiu,Li Juan,Wang Dong,Sun Xiaxia,Peng Yaping,Deng Jianjun

Abstract

Abstract Background The contact plate method is widely accepted and used in various fields where hygiene and contamination levels are crucial. Evidence regarding the applicability of the contact plate method for sampling fabric microbial contamination levels in real medical environments was limited. This study aimed to assess the applicability of the contact plate method for detecting microbial contamination on medical fabrics in a real healthcare environment, thereby providing a benchmark for fabric microbial sampling methods. Methods In a level three obstetrics ward of a hospital, twenty-four privacy curtains adjacent to patient beds were selected for this study. The contact plate and swab method were used to collect microbial samples from the privacy curtains on the 1st, 7th, 14th, and 28th days after they were hung. The total colony count on each privacy curtain surface was calculated, and microbial identification was performed. Results After excluding the effects of time, room type, and curtain location on the detected microbial load, the linear mixed-effects model analysis showed that contact plate method yielded lower colony counts compared to swab method (P < 0.001). However, the contact plate method isolated more microbial species than swab method (P < 0.001). 291 pathogenic strains were isolated using the contact plate method and 133 pathogenic strains were isolated via the swab method. There was no difference between the two sampling methods in the detection of gram-negative bacteria (P = 0.089). Furthermore, the microbial load on curtains in double-occupancy rooms was lower than those in triple-occupancy rooms (P = 0.021), and the microbial load on curtains near windows was lower than that near doors (P = 0.004). Conclusion Contact plate method is superior to swab method in strain isolation. Swab method is more suitable for evaluating the bacterial contamination of fabrics.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3