The poor accuracy of D-dimer for the diagnosis of prosthetic joint infection but its potential usefulness in early postoperative infections following revision arthroplasty for aseptic loosening

Author:

Fernandez-Sampedro M.,Sanlés-González I.,García-Ibarbia C.,Fañanás-Rodríquez N.,Fakkas-Fernández M.,Fariñas M. C.

Abstract

Abstract Background D-dimer was introduced in 2018 as an alternative biomarker for C-reactive protein (CRP) in the diagnostic of prosthetic joint infection (PJI) criteria of the Musculoskeletal Infection Society. We assessed the accuracy of plasma D-dimer for the diagnosis of early, delayed, and late PJI according to Infectious Diseases Society of America (IDSA) criteria, and whether persistently high levels of D-dimer in cases of aseptic loosening (AL) may be predictive of subsequent implant-related infection. Methods A prospective study of a consecutive series of 187 revision arthroplasties was performed at a single institution. Septic (n = 39) and aseptic revisions (n = 141) were classified based on IDSA criteria. Preoperative assessment of CRP, erythrocyte sedimentation rate (ESR) and D-dimer was performed. Receiver operating curves were used to determine maximum sensitivity and specificity of the biomarkers. The natural progress of D-dimer for AL cases was followed up either until the date of implant-related infection at any time during the first year or 1 year after revision in patients without failure. Clinical outcomes for those AL cases included infection-related failure that required a new surgery or need for antibiotic suppression. Results Preoperative D-dimer level was significantly higher in PJI cases than in AL cases (p = 0.000). The optimal threshold of D-dimer for the diagnosis of PJI was 1167 ng/mL. For overall diagnosis of PJI, C-reactive protein (CRP) achieved the highest sensitivity (84.6%), followed by erythrocyte sedimentation rate (ESR) and D-dimer (82% and 71.8%, respectively). Plasma D-dimer sensitivity was lower for all PJI types. When combinations of 2 tests were studied, the combined use of ESR and CRP achieved the best accuracy for all types of PJI (76.9%). 4.25% of AL cases had implant failure due to implant-related infection during the first year after the index revision arthroplasty, only the cases with early failure maintained high D-dimer levels. Conclusions Plasma D-dimer did not offer an improvement over the individual or combined diagnosis for any type of PJI according to IDSA criteria. Persistently raised levels of D-dimer after revision arthroplasty in AL cases might be used to effectively diagnose early postoperative infection.

Publisher

Springer Science and Business Media LLC

Subject

Infectious Diseases

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3