Comparing the broth enrichment-multiplex lateral flow immunochromatographic assay with real time quantitative PCR for the rapid detection of carbapenemase-producing organisms in rectal swabs

Author:

Wang Yue,Song Huijuan,Xu Min,Li Dengju,Ran Xiao,Sun Ziyong,Chen Zhongju

Abstract

Abstract Background Rapid and accurate identification of carbapenemase-producing organism (CPO) intestinal carriers is essential for infection prevention and control. Molecular diagnostic methods can produce results in as little as 1 h, but require special instrumentation and are expensive. Therefore, it is urgent to find an alternative method. The broth enrichment-multiplex lateral flow immunochromatographic assay was recently reported, but using it to directly detect CPO intestinal carriers in rectal swabs still requires the evaluation of many samples. The aim of this study was to compare the performance of these two methods, and to explore the control measures of CPO infection. Methods Through CPO selective culture, PCR and DNA sequencing, 100 rectal swabs confirmed to be CPO-positive and 100 rectal swabs with negative results were collected continuously. After eluting the rectal swabs with saline, three aliquots were used: one for counting, one for detection by Xpert Carba-R, and one for culture in broth for 0 h, 1 h, 2 h, 3 h and 4 h, followed by NG-Test CARBA 5 assessment. The sensitivity and specificity of the NG-Test CARBA 5 method after different incubation times were calculated. The limit of detection (LoD) of this assay after 4 h broth incubation was estimated by examining the bacterial suspensions and simulated faecal suspensions prepared with CPOs producing different types of carbapenemases. Results Xpert Carba-R demonstrated a combined sensitivity of 99.0% and specificity of 98.0%. The sensitivity and specificity were higher than 90.0% for the different enzyme types. The specificities of five common carbapenemases detected by the broth enrichment NG-Test CARBA 5 combined method after different incubation times were 100%. The sensitivities increased with increasing incubation time. At 4 h, the Klebsiella pneumoniae carbapenemase (KPC), New Delhi metallo-beta-lactamase (NDM), imipenemase (IMP), Verona integron-encoded metallo-beta-lactamase (VIM), and oxacillinase (OXA) -48 detection sensitivities were 93.0%, 96.3%, 100%, 100% and 85.7%, respectively. The LoDs were between 102 and 104 CFU/mL for all five enzymes after 4 h of incubation. Conclusions This investigation highlighted that the broth enrichment-multiplex lateral flow immunochromatographic assay can be used as a new method for screening CPOs in rectal swabs.

Funder

Special Foundation for National Science and Technology Basic Research Program of China

Natural Science Foundation of Hubei Province

Publisher

Springer Science and Business Media LLC

Subject

Infectious Diseases

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3