Diagnostic accuracy and utility of three dengue diagnostic tests for the diagnosis of acute dengue infection in Malaysia

Author:

Chong Zhuo LinORCID,Sekaran Shamala Devi,Soe Hui Jen,Peramalah Devi,Rampal Sanjay,Ng Chiu-Wan

Abstract

Abstract Background Dengue is an emerging infectious disease that infects up to 390 million people yearly. The growing demand of dengue diagnostics especially in low-resource settings gave rise to many rapid diagnostic tests (RDT). This study evaluated the accuracy and utility of ViroTrack Dengue Acute - a new biosensors-based dengue NS1 RDT, SD Bioline Dengue Duo NS1/IgM/IgG combo - a commercially available RDT, and SD Dengue NS1 Ag enzyme-linked immunosorbent assay (ELISA), for the diagnosis of acute dengue infection. Methods This prospective cross-sectional study consecutively recruited 494 patients with suspected dengue from a health clinic in Malaysia. Both RDTs were performed onsite. The evaluated ELISA and reference tests were performed in a virology laboratory. The reference tests comprised of a reverse transcription-polymerase chain reaction and three ELISAs for the detection of dengue NS1 antigen, IgM and IgG antibodies, respectively. The diagnostic performance of evaluated tests was computed using STATA version 12. Results The sensitivity and specificity of ViroTrack were 62.3% (95%CI 55.6–68.7) and 95.0% (95%CI 91.7–97.3), versus 66.5% (95%CI 60.0–72.6) and 95.4% (95%CI 92.1–97.6) for SD NS1 ELISA, and 52.4% (95%CI 45.7–59.1) and 97.7% (95%CI 95.1–99.2) for NS1 component of SD Bioline, respectively. The combination of the latter with its IgM and IgG components were able to increase test sensitivity to 82.4% (95%CI 76.8–87.1) with corresponding decrease in specificity to 87.4% (95%CI 82.8–91.2). Although a positive test on any of the NS1 assays would increase the probability of dengue to above 90% in a patient, a negative result would only reduce this probability to 23.0–29.3%. In contrast, this probability of false negative diagnosis would be further reduced to 14.7% (95%CI 11.4–18.6) if SD Bioline NS1/IgM/IgG combo was negative. Conclusions The performance of ViroTrack Dengue Acute was comparable to SD Dengue NS1 Ag ELISA. Addition of serology components to SD Bioline Dengue Duo significantly improved its sensitivity and reduced its false negative rate such that it missed the fewest dengue patients, making it a better point-of-care diagnostic tool. New RDT like ViroTrack Dengue Acute may be a potential alternative to existing RDT if its combination with serology components is proven better in future studies.

Funder

Markedsmodningsfonden

Publisher

Springer Science and Business Media LLC

Subject

Infectious Diseases

Reference56 articles.

1. World Health Organization. Global strategy for dengue prevention and control 2012–2020. Geneva: World Health Organization; 2012.

2. Bhatt S, Gething PW, Brady OJ, Messina JP, Farlow AW, Moyes CL, et al. The global distribution and burden of dengue. Nature. 2013;496:504–7.

3. Faraji A, Unlu I. The eye of the Tiger, the thrill of the fight: effective larval and adult control measures against the Asian Tiger mosquito, Aedes albopictus (Diptera: Culicidae), in North America. J Biomed Inform. 2014;48:193–204.

4. idengue untuk komuniti: Senarai Kawasan Cluster Dengue 2016 [Available from: http://idengue.remotesensing.gov.my/idengue/page2.php?kandungan=lokaliti_wabak.php.

5. Ministry of Health. Clinical Practice Guidelines: Management of Dengue Infection in Adults. 3rd ed. Putrajaya: Malaysia Health Technology Assessment Section; 2015.

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3