The effectiveness of different irrigation strategies with laser activation on the bond strength of MTA as root end filling material: in vitro study

Author:

Mostafa Nada OmarORCID,Kabel Nihal Refaat,Masoud Muhammad Abbass

Abstract

Abstract Objective To compare the push out bond strength of MTA apical plug in a simulated immature root, after using different irrigation protocols; NaOCl + 20% Etidronic acid (HEBP) and NaOCl + 17% Ethylenediaminetetraacetic acid (EDTA) with and without diode laser activation. Methods Twenty-eight extracted single straight rooted permanent human teeth were selected. The root lengths were standardized (15 mm) by decronation of all samples. Instrumentation was done using the ProTaper Next system (Dentsply Sirona), the canals were flushed with 1 mL NaOCL after each instrument. Then, the apical 3 mm was cut perpendicular to the root’s long axis and the canals were prepared till file 90( master file) using the balanced force technique to simulate immature teeth. Samples were divided into four experimental groups (n = 7) in accordance with the irrigation protocol; G1 (NaOCl + HEBP), G2 (NaOCl + EDTA) both G1 and G2 were activated with diode laser, while G3 (NaOCl + HEBP) and G4 (NaOCl + EDTA) were activated with manual agitation. Canals were filled with a 5-mm MTA (ProRoot MTA, Dentsply Tulsa Dental) apical plug. Each root was transversely sectioned perpendicular to their long axis to have a 3 mm ± 0.1sections in thickness from the root apical portion. A push-out test was performed, and the failure pattern was assessed. Push out bond strength values were analyzed with student t test for compared pairs. Two-way ANOVA was used to detect the effect of each variable (chelating agent with/without laser activation). Result Effect of diode laser activation in G1 and G2 showed no significant differences (p > 0.05) on the push out bond strength values of MTA, while in manual activated groups (G3 and G4), there was a statistically significant difference (p < 0.05) where G4 recorded higher push out bond strength mean values than G3. Conclusions The diode laser activation when used with NaOCL and HEBP increased the effect of HEBP as chelating agent and improved the push out strength values of MTA, rendering it an alternative mild chelating agent in comparison with the EDTA.

Publisher

Springer Science and Business Media LLC

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3