Diagnostic accuracy of D-dimer in periprosthetic joint infection: a diagnostic meta-analysis

Author:

Zhang Haitao,Sun Xiaobo,Xin Pengfei,Zhu Xingyang,Jie Ke,Cao Houran,Feng Wenjun,Zeng Yuqing,Lv Yan,Chen Jinlun,Li Jie,Zeng Jianchun,Zeng Yirong

Abstract

Abstract Background Periprosthetic joint infection (PJI) is one of the most devastating complications after total joint replacement (TJA). Up to now, the diagnosis of PJI is still in a dilemma. As a novel biomarker, whether D-dimer is valuable in the diagnosis of PJI remains controversial. This meta-analysis attempts to determine the diagnostic accuracy of D-dimer in PJI. Methods Relevant literature was retrieved from PubMed, Embase, Web of Science, and Cochrane Library (from database establishment to April 2020). Literature quality was evaluated using Revman (version 5.3). The random effect model was used in the Stata version 14.0 software to combine sensitivity, specificity, likelihood ratio (LR), diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curve, and area under SROC (AUC) to evaluate the diagnostic value of overall D-dimer for PJI. Meta regression and subgroup analysis were performed according to the threshold, the study design, the sample size, the diagnostic gold standard, the country of study, and the type of sample. Results A total of 9 studies were included in this study, including 1592 patients. The pooled sensitivity and specificity of D-dimer for PJI diagnosis are 0.82 (95% CI, 0.72~0.89) and 0.73 (95% CI, 0.58~0.83), respectively. The pooled positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 2.99 (95% CI, 1.84~4.88) and 0.25 (95% CI, 0.15~0.41), respectively. The pooled AUC and diagnostic odds ratios were 0.85 (95% CI, 0.82~0.88) and 12.20 (95% CI, 4.98~29.86), respectively. Conclusion D-dimer is a promising biomarker for the diagnosis of PJI, which should be used in conjunction with other biomarkers or as an adjunct to other diagnostic methods to enhance diagnostic performance.

Funder

High-Level University Construction Project of Guangzhou University of Chinese Medicine

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3