Efficacy of high-intensity home mechanical stretch therapy for treatment of shoulder stiffness: a retrospective review

Author:

Stinton Shaun,Beckley Samantha,Salamani Alicia,Dietz Devinne,Branch Thomas

Abstract

Abstract Background Shoulder stiffness resulting in motion loss can be caused by numerous conditions, the most common of which is adhesive capsulitis. Surgical intervention is often necessary when conservative methods fail. High-intensity stretch (HIS) treatment may be able to provide increased motion gains while avoiding the cost and complications of surgery. Objectives The purpose of this study was to review data from patients who were prescribed a HIS device to recover their shoulder motion to determine the efficacy of the device. The hypotheses were that patients would achieve significant range of motion (ROM) gains and that ROM would increase to a level at which patients would be able to avoid a motion loss surgery and perform activities of daily living. Methods Clinical notes were reviewed for patients whose progress plateaued after 4 weeks of therapy and were subsequently prescribed the HIS device after failing to meet their treatment goals. ROM data were recorded for external rotation, abduction, forward flexion, and internal rotation. Pre- and post-treatment ROM data were compared using t-tests. Results Significant ROM gains were seen in all planes of motion (p < 0.001). Patients gained an average of 29.9° in external rotation with a last recorded rotation of 59.2°. In abduction, patients gained 40.5° with a last recorded abduction of 123.3°. In forward flexion, patients gained 30.3° with a last recorded flexion of 138.7°. In internal rotation, patients gained 15.2° with a last recorded rotation of 57.6°. These last recorded ranges of motion were sufficient to perform nearly all activities of daily living. Conclusions The HIS device was effective in treating patients with shoulder motion loss as demonstrated by the significant ROM gains in all planes of motion. The ability for a patient to recover lost motion quickly without surgery is of great value to quality of life and in healthcare cost savings. We believe this high-intensity stretch device should be considered for use by patients who are at risk for a motion loss surgery.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3