The effect of femoral prosthesis design on patellofemoral contact stresses in total knee arthroplasty: a case–control study with mid-term follow-up minimum 3-year follow-up

Author:

Kong Lingce,Lin Wei,Kang Huijun,Li Ming,Hao Kuo,Chang Bo,Wang Fei

Abstract

Abstract Background To investigate the differences in postoperative patellofemoral pressures and patellar tracking during at least three years of follow-up in patients using three prostheses of different designs in total knee arthroplasty (TKA) without patellar resurfacing. Methods: Radiographic investigations The study included 401 patients who had a total of 480 knee prostheses implanted without patellar resurfacing. The prostheses used were Genesis II (external rotation design of femoral prosthesis), Triathlon (design with deep trochlear grooves), and Gemini MK II (deepening of trochlear groove and lateral condylar protrusion that closely follows the anatomical shape). The patients' patellar tracking was assessed by measuring patellar tilt and displacement during postoperative follow-up. Furthermore, postoperative knee function and pain were evaluated through range of motion, Knee Society scores (KSS), and Forgotten Joint Score (FJS) to compare the different groups. Finite element analysis Constructing a finite element model of the knee joint of a normal volunteer after total knee arthroplasty using different prostheses for nonpatellar replacement. The three models' von Mises stress distribution heat map, peak contact pressure, and patellar transverse displacement were compared at 30°, 60°, and 90°, respectively. Results: Radiographic investigations A total of 456 knees of 384 patients were investigated at a 3-year follow-up after TKA without patellar resurfacing. There were no significant differences in patellar tracking between the three groups. Patients with all three prostheses demonstrated favorable clinical outcomes at 3 years postoperatively, with no statistically significant differences in knee scores (91.9 vs 92.3 vs 91.8) or range of motion (127.9° vs 128.5° vs 127.7°) between the groups. However, there was a significant difference between Genesis II and Gemini MK II in the Forgotten Joint Score (59.7 vs 62.4). Patients with persistent postoperative anterior knee pain were present in all three groups (16 vs 12 vs 10), but the incidence was not significantly different. Finite element analysis The von Mises stress distribution heat map showed that during flexion, the patellofemoral stresses were mainly concentrated on the lateral side of the prosthesis side, and the contact site gradually shifted downward with increasing flexion angle. At the same time, the peak contact stress of the patellofemoral joint increased with the gradual increase in the flexion angle. Genesis II, with a wider and shallower trochlear groove, showed greater patellofemoral stresses and lateral patellar displacement after TKA without patellar resurfacing. The Gemini MK II with a deeper trochlear groove and slightly protruding lateral condyle is more in line with anatomical design, with smaller patellofemoral joint pressure and better patellar tracking. Conclusions In TKA without patellar resurfacing, a prosthesis with a deeper trochlear groove, a slightly higher lateral femoral condyle, and a more anatomically designed knee that better matches the patellar morphology should be a better choice.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3