Biomechanical comparison of noncontiguous cervical disc arthroplasty and noncontiguous cervical discectomy and fusion in the treatment of noncontinuous cervical degenerative disc disease: a finite element analysis

Author:

Sun Xiangyao,Sun Siyuan,Zhang Tongtong,Kong Chao,Wang Wei,Lu ShibaoORCID

Abstract

Abstract Background Biomechanical characteristics of noncontinuous ACDF and noncontinuous CDA in the treatment of noncontinuous cervical degenerative disc disease were still unclear. The aim of this research is to compare the differences between these two kinds of treatment methods and to verify the effectiveness of Prodisc-C in noncontinuous CDA. Methods Eight FEMs of the cervical spine (C2–C7) were built based on CT images of 8 mild CDDD volunteers. In the arthroplasty group, we inserted Prodisc-C at C3/4 and C5/6. In the fusion group, CoRoent® Contour and NuVasive® Helix ACP were implanted at C3/4 and C5/6. Initial loads of 75 N were used to simulate the head weight and muscle forces. The application of 1.0 N m moment on the top on the C2 vertebra was used to create motion in all directions. Statistical analyses were performed using STATA version 14.0 (Stata Corp LP, College Station, Texas, USA). Statistical significance was set at P < 0.05. Results The IDPs in C2/3 (P < 0.001, P = 0.005, P < 0.001, P < 0.001), C4/5 (P < 0.001), and C6/7 (P < 0.001) of the intact group were significantly less than that in the fusion group in flexion, extension, lateral bending, and axial rotation, respectively. In addition, the IDPs in C2/3 (P < 0.001, P = 0.001, P < 0.001, P < 0.001), C4/5 (P < 0.001), and C6/7 (P < 0.001) of the arthroplasty group were significantly less than that in the fusion group in flexion, extension, lateral bending, and axial rotation, respectively. Contact forces of facet joints in C2/3 (P = 0.010) in the arthroplasty group was significantly less than that in the intact group. Contact forces of facet joints in C2/3 (P < 0.001), C4/5 (P < 0.001), and C6/7 (P < 0.001) in the arthroplasty group was significantly less than that in the fusion group. Contact forces of facet joints in C2/3 (P < 0.001), C4/5 (P < 0.001), and C6/7 (P < 0.001) in the intact group were significantly less than that in the fusion group. Conclusions Noncontinuous CDA could preserve IDP and facet joint forces at the adjacent and intermediate levels to maintain the kinematics of cervical spine near preoperative values. However, noncontinuous ACDF would increase degenerative risks at adjacent and intermediate levels. In addition, the application of Prodisc-C in noncontinuous CAD may have more advantages than that of Prestige LP.

Funder

China Scholarship Council

National Natural Science Foundation of China

Beijing Municipal Commission of Health and Family Planning

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3