Can accuracy of component alignment be improved with Oxford UKA Microplasty® instrumentation?

Author:

Ng Jonathan Patrick,Fan Jason Chi Ho,Lau Lawrence Chun ManORCID,Tse Tycus Tao Sun,Wan Samuel Yik Cheung,Hung Yuk Wah

Abstract

Abstract Background One factor in the long-term survivorship of unicompartmental knee arthroplasty is the accuracy of implantation. In addition to implant designs, the instrumentation has also evolved in the last three decades to improve the reproducibility of implant placement. There have been limited studies comparing mobile bearing unicompartmental knee arthroplasty with contemporary instrumentation and fixed bearing unicompartmental knee arthroplasty with conventional instrumentation. This study aims to determine whether the Microplasty instrumentation in Oxford unicompartmental knee arthroplasty allows the surgeon to implant the components more precisely and accurately. Methods A total of 150 patients (194 knees) were included between April 2013 and June 2019. Coronal and sagittal alignment of the tibial and femoral components was measured on postoperative radiographs. Component axial rotational alignment was measured on postoperative computer tomography. The knee rotation angle was the difference between the femoral and tibial axial rotation. A rotational mismatch was defined as a knee rotation angle of > 10°. Statistical analysis was performed using Student t test and Mann-Whitney nonparametric test. A p value < 0.05 was considered statistically significant in each analysis. Results Between April 2013 to June 2019, 112 patients (150 knees) received Oxford unicompartmental knee arthroplasty, one patient (2 knees) had Journey unicompartmental knee arthroplasty, and 37 patients (42 knees) received Zimmer unicompartmental knee arthroplasty. All femoral components in the Oxford group were implanted within the reference range, compared with 36.6% in the fixed bearing group (p < 0.001). 88.3% of Oxford knees had tibial component falling within the reference range, whereas 56.1% of knees in the fixed bearing group fell within the reference range (p < 0.001). 97.5% of Oxford knees had tibial slope that fell within reference range, whereas 53.7% fell within range for fixed bearing group (p < 0.001). Femorotibial rotational mismatch of more than 10° was noted in 13.8% in Oxford group and 20.5% in fixed bearing group (p = 0.04). Conclusion In conclusion, Microplasty instrumentation for Oxford mobile bearing unicompartmental knee arthroplasty is more accurate and precise compared to conventional fixed bearing unicompartmental knee arthroplasty in sagittal, coronal, and axial alignment. Prospective studies with long-term follow-up are warranted to investigate the clinical implications.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3