Author:
Chen Zhijie,Li Bin,Chen Kaizhe,Feng Jianmin,Wang Yi,Liu Zhihong,He Chuan
Abstract
Abstract
Purpose
Short tapered stem placement has been extensively employed in total hip arthroplasty (THA). Suboptimal fixation tends to cause postoperative complications, such as thigh pain. However, it remains unclear whether poor seating/alignment of short tapered stems contributes to thigh pain. In this study, we retrospectively examined the factors that might be associated with thigh pain.
Methods
Medical records of 230 patients who had undergone THAs at our hospital were reviewed retrospectively. All patients received the same mediolateral (ML) short tapered femoral stems. The association between thigh pain and patients’ demographics, radiographic findings, or the type of fitting of the femoral stems was investigated.
Results
In our cohort, 68 patients (27.8%) presented with thigh pain. Among 203 type I fit patients, 62 (30.5%) developed thigh pain, while only 6 out of 43 (12.2%) type II fit patients had thigh pain, with the differences being statistically significant (x2 = 6.706, p = 0.01). In addition, hip anteroposterior radiographs exhibited that the stem angulation (mean 2.52°), the variation in angulation (mean 1.32°), and the extent of femoral stem subsidence (mean 0.29 cm) were greater in patients with thigh pain than in their counterparts without thigh pain (all p < 0.05).
Conclusion
Malalignment and improper seating of short tapered stems could be at least one of the reasons for post-THA thigh pain. The distal contact between the stem tip and the medial femoral cortex might result in thigh pain. Our study suggested that distal implant contact should be avoided, and stem alignment should be meticulously performed in the placement of ML short tapered femoral stems for THA.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献