Inadequate proximal screw fixation increases risk of failure following plate fixation of diaphyseal humerus fractures

Author:

Mistry Manisha R.,Tat Jimmy,Husain Rafi,Sheth Ujash,Richards Robin R.,Nam Diane

Abstract

Abstract Background Operative treatment of humeral shaft fractures (AO/OTA 12) is being performed more frequently. Accordingly, it is important to understand the complications associated with plate fixation. This study analyzes risk factors associated with mechanical failure following plate fixation of humeral shaft fractures in order to further elucidate the mode and location of failure. Methods A retrospective review of 351 humeral shaft fractures was completed at a single level I trauma center. Eleven of eighty-five humeral shaft fractures had aseptic mechanical failure requiring revision (12.9%), following initial plate fixation. Fracture characteristics (AO type, comminution, location) and fracture fixation (plate type, multiplanar, number of screws proximal and distal to the fracture) were compared between aseptic mechanical failure and those without failure. A forward stepwise logistic regression analysis was performed to determine any significant predictors of aseptic mechanical failure. Results There was significant differences in fixation between the aseptic mechanical failure group and those without failure, specifically in the number of screws for proximal fixation (p = 0.008) and distal fixation (p = 0.040). In the aseptic mechanical failure group, patients tended to have less than < 8 cortices of proximal fixation (82%) and less than < 8 cortices of distal fixation (64%). Conversely, in patients without mechanical failure there was a tendency to have greater than > 8 cortices in both the proximal (62%) and distal fixation (70%). A forward stepwise logistic regression analysis found that less than < 8 cortices of proximal fixation was a significant predictor of aseptic failure, OR 7.96 (p = 0.011). We think this can be accounted for due to the variable bone quality, thinner cortices and multiple torsional forces in the proximal shaft that may warrant special consideration for fixation. Conclusion The current dogma of humeral shaft fracture stabilization is to use a minimum of 3 screws proximal and distal to the fracture, however the current study demonstrates this is associated with higher rates of mechanical failure. In contrast, 4 bicortical screws or more of fixation on either side of the fracture had lower failure rates and may help to reduce the risk of mechanical failure. Level of Evidence Level III.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3