The proximal humeral locking plate positioning to the pectoralis major tendon in achieving the proper calcar screw location: a cadaveric study

Author:

Kulkamthorn Nattha,Rungrattanawilai Naruebade,Tarunotai Thanakorn,Chuvetsereporn Nantaphon,Chansela Piyachat,Phruetthiphat Ong-art

Abstract

Abstract Background Proximal humeral fracture is the third most common of osteoporotic fracture. Most surgical cases were treated by fixation with anatomical locking plate system. The calcar screw plays a role in medial support and improving varus stability. Proximal humerus fracture in elderly patients are commonly seen with greater tuberosity (GT) fracture. The GT fragment is sometimes difficult to use as an anatomic landmark for proper plate and screw position. Therefore, the insertion of pectoralis major tendon (PMT) may be used as an alternative landmark for appropriate plate and calcar screw position. The purpose of study is going to identify the vertical distance from PMT to a definite point on the position of locking plate. Methods 30 cadaveric shoulders at the department of clinical anatomy were performed. Shoulders with osteoarthritic change (n = 5) were excluded. Finally, 25 soft cadaveric shoulders were recruited in this study. The PHILOS™ plate was placed 2 mm posterior to the bicipital groove. A humeral head (HH) was cut in the coronal plane at the level of the anterior border of the PHILOS plate with a saw. A calcar screw was inserted close to the inferior cortex of HH. Distance from the upper border of elongated combi-hole (UB-ECH) to the upper border of pectoralis major tendon (UB-PMT) was measured. The plate was then moved superiorly until the calcar screw was 12 mm superior to the inferior border of HH and the distance was repeatedly measured. Results The range of distance from UB-PMT to the UB-ECH was from − 4.50 ± 7.95 mm to 6.62 ± 7.53 mm, when calcar screw was close to inferior border of HH and when the calcar screw was 12 mm superior to the inferior border of HH, respectively. The highest probability of calcar screw in proper location was 72% when UB-ECH was 3 mm above UB-PMT. Discussion and conclusion The GT fragment is sometimes difficult to use as an anatomic landmark for proper plate and screw position. PMT can be used as an alternative anatomic reference. UB-PMT can serve as a guide for proper calcar screw insertion. UB-ECH should be 3 mm above UB-PMT and three-fourths of cases achieved proper calcar screw location.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3