Abstract
Abstract
Background
In tibial plateau fractures (TPF) the restoration of an anatomical joint surface as well as an exact subchondral screw position for postoperative stability is crucial for the outcome.
The aim of this study was to determine whether the additional use of an intraoperative 3D imaging intensifier (3D) might help to improve the outcome of complex TPF.
Methods
We performed a retrospective case-control study of a level 1 trauma center. Patients with AO/OTA 41 B3 and C-TPF operated on using a 3D imaging intensifier between November 2015 and December 2018 (3D group) were included. The outcomes of this patients were compared to patients operated without 3D imaging between January 2005 to December 2014 (2D group). The comparison of the groups was performed by matched pair analysis. The functional outcome of both groups was measured by KOOS and Lysholm Score after a follow-up period of at least 12 months. Operation time, infections and postoperative revisions were registered.
Results
In total, 18 patients were included in the 3D group (mean age: 51.0± 16.4 years; 12 females) and an equal number of matching partners from the 2D group (mean age: 50.3± 15.2 years; 11 females) were found (p=0.82; p=0.79). We found 9x B3, 2x C1, 1x C2, 6x C3 fractures according to AO/OTA for each group (p=1.00) with comparable ASA score (p=0.27). The mean operation time was 127.9± 45.9 min and 116.1± 45.7 min for the 3D and 2D group (p=0.28). The mean follow-up time was 20.9± 10.7 months for the 3D and 55.5± 34.7 months for the 2D group (p< 0.001). For the 3D group a mean Lysholm overall score of 67.4± 26.8 and KOOS overall score of 72.6± 23.5 could be assessed. In contrast, a mean Lysholm overall score of 62.0± 21.4 and KOOS overall score of 65.8± 21.6 could be measured in the 2D group (p=0.39; p=0.31). Thereby, functional outcome of the 3D group showed a significant higher KOOS Sport/Rec sub score of 54.7± 35.0 in comparison to the 2D group with 26.7± 31.6 (p= 0.01). Postoperative revisions had to be performed in 27.8% of cases in both groups (p=1.00). Due to the 3D imaging an intraoperative revision was performed in 33.3% (6/18).
Conclusion
In our study we could show that re-reduction of the fracture or implant re-positioning were performed in relevant numbers based on the 3D imaging. This was associated with a midterm clinical benefit in regard to better KOOS Sport/Rec scores.
Trial registration
AZ 488 /20-ek
Funder
Universitätsklinikum Leipzig
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Reference39 articles.
1. Tscherne H, Lobenhoffer P. Tibial plateau fractures. Management and expected results. Clin Orthop Related Res. 1993:87–100.
2. Rademakers M, Kerkhoffs G, Sierevelt I, Raaymakers E, Marti R. Operative treatment of 109 tibial plateau fractures: five-to 27-year follow-up results. J Orthopaedic Trauma. 2007;21(1):5–10. https://doi.org/10.1097/BOT.0b013e31802c5b51.
3. Elsoe R, Larsen P, Nielsen NPH, Swenne J, Rasmussen S, Ostgaard SE. Population-Based Epidemiology of Tibial Plateau Fractures. Orthopedics. 2015;38(9):e780–6. https://doi.org/10.3928/01477447-20150902-55.
4. Manidakis N, Dosani A, Dimitriou R, Stengel D, Matthews S, Giannoudis P. Tibial plateau fractures: functional outcome and incidence of osteoarthritis in 125 cases. International orthopaedics. 2010;34(4):565–70. https://doi.org/10.1007/s00264-009-0790-5.
5. McNamara IR, Smith TO, Shepherd KL, Clark AB, Nielsen DM, Donell S, et al. Surgical fixation methods for tibial plateau fractures. Cochrane Database of Systematic Reviews [Internet]. John Wiley & Sons, Ltd; 2015 [cited 2021 Mar 14]; Available from: https://www.cochranelibrary.com/cdsr/doi/10.1002/14651858.CD009679.pub2/full
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献