Can mobile-bearing unicompartmental knee arthroplasty achieve natural gap-balancing? An observational study with a novel pressure sensor

Author:

Nan Shaokui,Cao Zheng,Song Yue,Kong Xiangpeng,Li Haifeng,Chai Wei

Abstract

Abstract Background Mobile-bearing unicompartmental knee arthroplasty (MB-UKA) is an effective treatment for anteromedial knee osteoarthritis. Meticulous intraoperative soft tissue balancing remains challenging yet consequential for a successful operation. Currently, surgeons rely mostly on their experience during soft tissue balancing, yielding unreproducible results. The purpose of this study was to quantified measure the soft tissue tension of medial compartment and determine if an optimal "target" tension values with the natural state exists. Methods This was an observational study of 24 consecutive patients. All 30 UKAs were performed by a single surgeon. The piezoresistive sensor was custom designed to fit in the medial compartment gap. Contact pressures were measured at 5 angular positions of the knee intraoperatively: 0°, 20°, 45°, 90°, and 110° of flexion. The change in pressure from extension (20° position) and flexion (110° position) was also calculated (E-FPD). Data on age, sex, body mass index, operative side, and bearing size were collected. Outcome measures were measured at baseline and at the 6-month postoperative follow-up; Oxford Knee Score, visual analog scale score, and range of motion were compared to evaluate clinical outcomes. Results There was a significant improvement in patients in all measured outcomes at 6 months from baseline (P < 0.05). The E-FPD of 14.9 N (8.9, 24.6) was indicative of appropriate soft tissue balancing throughout the functional range of knee motion. Of 30 knees, 22 were 3-mm bearing and 8 were 4- or 5-mm bearing. The pressure data of the 3-mm bearing group was larger than that of the non-3-mm bearing group for each knee flexion degree, but the difference was not statistically significant (P > 0.05). Conclusions Objective data from sensor output may assist surgeons in decreasing loading variability during MB-UKA. The data suggested that MB-UKA could not accurately restore soft tissue tension to the natural state, which was related to the inability of MB-UKA surgical instruments to fine adjust the bone cut and soft tissue release. Study registration Chinese Clinical Trial Registry (http://www.chictr.org.cn): ChiCTR1900024146.

Funder

Beijing Municipal Natural Science Foundation

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3