Automated measurement of alpha angle on 3D-magnetic resonance imaging in femoroacetabular impingement hips: a pilot study

Author:

Ewertowski Nastassja Pamela,Schleich Christoph,Abrar Daniel Benjamin,Hosalkar Harish S.,Bittersohl Bernd

Abstract

AbstractBackgroundFemoroacetabular impingement (FAI) syndrome is an established pre-osteoarthritic condition. Diagnosis is based on both clinical and radiographic parameters. An abnormal manually calculated alpha angle in magnetic resonance imaging (MRI) is traditionally utilized to diagnose abnormal femoral head-neck offset. This pilot study aimed to assess the feasibility of automated alpha angle measurements in patients with FAI syndrome, and to compare automated with manual measurements data with regard to the time and effort needed in each method.MethodsAlpha angles were measured with manual and automated techniques, using postprocessing software in nineteen hip MRIs of FAI syndrome patients. Two observers conducted manual measurements. Intra- and inter-observer reproducibility and correlation of manual and automated alpha angle measurements were calculated using intra-class correlation (ICC) analysis. Both techniques were compared regarding the time taken (in minutes) and effort required, measured as the amount of mouse button presses performed.ResultsThe first observer’s intra-observer reproducibility was good (ICC 0.77; p < 0.001) while the second observer’s was good-to-excellent (ICC 0.93; p < 0.001). Inter-observer reproducibility between both observers in the first (ICC 0.45; p < 0.001) and second (ICC 0.56; p < 0.001) manual alpha angle assessment was moderate. The intra-class correlation coefficients between manual and automated alpha angle measurements were ICC = 0.24 (p = 0.052; observer 1, 1st measurement), ICC = 0.32 (p = 0.015; observer 1, 2nd measurement), ICC = 0.50 (p < 0.001; observer 2, 1st measurement), and ICC = 0.45 (p < 0.001; observer 2, 2nd measurement). Average runtime for automatic processing of the image data for the automated assessment was 16.6 ± 1.9 min. Automatic alpha angle measurements took longer (time difference: 14.6 ± 3.9 min; p < 0.001) but required less effort (difference in button presses: 231 ± 23; p < 0.001). While the automatic processing is running, the user can perform other tasks.ConclusionsThis pilot study demonstrates that objective and reliable automated alpha angle measurement of MRIs in FAI syndrome hips is feasible.Trial registrationThe Ethics Committee of the University of Düsseldorf approved our study (Registry-ID: 2017084398).

Funder

Universitätsklinikum Düsseldorf. Anstalt öffentlichen Rechts

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3