Author:
Tang Yifan,Geng Xiangwu,Li Fengning,Sun Yanqing,Jia Lianshun,Zhou Shengyuan,Chen Xiongsheng
Abstract
Abstract
Purpose
To analyze risk factors of titanium mesh cage (TMC) subsidence in single-level anterior cervical corpectomy and fusion (ACCF) for cervical ossification of the posterior longitudinal ligament (OPLL).
Methods
TMC subsidence is defined as the reduction of the adjacent vertebral bodies by ≥ 2 mm. Patients with cervical OPLL who were treated with single-level ACCF between January 2019 and May 2021 were retrospectively analyzed in two groups: patients with TMC subsidence as Group S and patients with no TMC subsidence as Group N during the one-year follow-up period. The degree of distraction of surgical segment and correction of the cervical curvature was measured to analyze their relationship with TMC subsidence.
Results
A total of 128 patients were included in Group S, and 138 patients were included in Group N. There was no significant difference in patient demographics and complications between the two groups. The degree of distraction in Group S was significantly higher than that in Group N (11.4% ± 7.6% vs. 4.7% ± 9.7%, P < 0.01). The change of C2 to C7 Cobb angle (α) in Group S was significantly greater than that in Group N (5.7 ± 2.7 vs. 1.4 ± 4.7, P < 0.01), and the change of interspinous process distance (SPD) in Group S was also significantly greater than that in Group N (7.0 ± 4.2 vs. 4.1 ± 2.7, P < 0.01). The JOA score and JOA recovery rate were not statistically different between the two groups.
Conclusions
Intraoperative selection of overlength TMC in single-level ACCF for OPLL, over-distraction and excessive correction of the cervical curvature may cause TMC subsidence after surgery. No significant impact of TMC subsidence on the surgical outcome was observed during the 1-year follow-up period.
Funder
National Natural Science Foundation of China
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Reference28 articles.
1. Eck KR, Bridwell KH, Ungacta FF, Lapp MA, Lenke LG, Riew KD. Analysis of titanium mesh cages in adults with minimum two-year follow-up. Spine. 2000;25(18):2407–15.
2. Chuang HC, Cho DY, Chang CS, Lee WY, Jung-Chung C, Lee HC, et al. Efficacy and safety of the use of titanium mesh cages and anterior cervical plates for interbody fusion after anterior cervical corpectomy. Surg Neurol. 2006;65(5):464–71 (discussion 71).
3. Kanayama M, Hashimoto T, Shigenobu K, Oha F, Ishida T, Yamane S. Pitfalls of anterior cervical fusion using titanium mesh and local autograft. J Spinal Disord Tech. 2003;16(6):513–8.
4. Wen Z, Lu T, Wang Y, Liang H, Gao Z, He X. Anterior cervical corpectomy and fusion and anterior cervical discectomy and fusion using titanium mesh cages for treatment of degenerative cervical pathologies: a literature review. Med Sci Monit Int Med J Exp Clin Res. 2018;24:6398–404.
5. Sawin PD, Traynelis VC, Menezes AH. A comparative analysis of fusion rates and donor-site morbidity for autogeneic rib and iliac crest bone grafts in posterior cervical fusions. J Neurosurg. 1998;88(2):255–65.