Primary total hip arthroplasty using a short bone-conserving stem in young adult osteoporotic patients with Dorr type C femoral bone

Author:

Zhen PingORCID,Chang Yanfeng,Yue Heng,Chen Hui,Zhou Shenghu,Liu Jun,He Xiaole

Abstract

Abstract Background Dorr type C femoral bone exhibits a wide, stovepipe-shaped femoral canal, and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation. Methods A total of 42 hip arthroplasties were performed in 35 young patients (range 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m2 (range, 16.8–23.2 kg/m2). According to Dorr’s criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index ≤ 3). Results The mean follow-up period was 5.5 years (range 3.0 to 8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0 ± 0.5 points (range, 1.0–4.0 points), which significantly improved to 7.5 ± 0.7 points (range 6.0 to 8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutrally to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up. Conclusions Based on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.

Funder

the National Natural Science Foundation

the Youth Science and Technology Foundation of Gansu Province

Natural Science Foundation of Shaanxi Province

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3