Reliability and validity of a mobile application for femoral anteversion measurement in adult patients

Author:

Lee Joon Woo,Oh Minjoon,Choi Mi Na,Lee Seung Yeol

Abstract

Abstract Background Femoral torsion is primarily measured by computed tomography (CT), which has cost and radiation exposure concerns. Recently, femoral anteversion measurement by a simple radiograph-based mobile application was developed for patients with cerebral palsy. This study aimed to validate the use of a mobile application that can reconstruct a three-dimensional model of the femur from conventional radiographs for adults. Methods Medical records of 76 patients undergoing conventional femur anteroposterior/lateral radiography and femur CT were reviewed. To measure femoral anteversion on the reconstructed 3-dimensional images from both the mobile application and CT, we drew a line which connects the posterior margins of each femoral condyle and another line which passes through the center of the femoral head and the midpoint of the femoral neck. After the reliability test, a single examiner measured femoral anteversion on the mobile application and CT. Pearson’s correlation analysis was used to assess the correlation between anteversion on the mobile application and CT. Results Femoral anteversion measured on both CT and the mobile application showed excellent reliability (intraclass correlation coefficients: 0.808–0.910). The correlation coefficient between femoral anteversion measured using CT and the mobile application was 0.933 (p < 0.001). The correlation of femoral anteversion between CT and the mobile application was relatively higher in the absence of metallic implants (correlation coefficient: 0.963, p < 0.001) than in the presence of metallic implants (correlation coefficient: 0.878, p < 0.001). Conclusions Using two simple radiographs, the mobile application showed excellent validity and reliability for femoral anteversion measurement in adults as compared to CT. With the high accessibility and cost-effectiveness of this mobile application, femoral torsion measurement might be easily performed with simple radiography in clinical settings in the near future.

Funder

Ministry of health & welfare, Korea

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3