The most appropriate titanium mesh cage size for anterior spinal reconstruction after single-level lumbar total en bloc spondylectomy: a finite element analysis and cadaveric validation study

Author:

Paholpak PermsakORCID,Sirichativapee Winai,Wisanuyotin Taweechok,Kosuwon Weerachai,Kasai Yuichi,Murakami Hideki

Abstract

Abstract Purpose There is little information available regarding the cage diameter that can provide the most rigid construct reconstruction after total en bloc spondylectomy (TES). The aim of this study was thus to determine the most appropriate titanium mesh cage diameter for reconstruction after spondylectomy. Methods A finite element model of the single level lumbar TES was created. Six models of titanium mesh cage with diameters of 1/3, 1/2, 2/3, 3/4, 4/5 of the caudad adjacent vertebra, and 1/1 of the cephalad vertebra were tested for construct stiffness. The peak von Mises stress (MPa) at the failure point and the site of failure were measured as outcomes. A cadaveric validation study also conducted to validate the finite element model. Results For axial loading, the maximum stress points were at the titanium mesh cage, with maximum stress of 44,598 MPa, 23,505 MPa, 23,778 MPa, and 16,598 MPa, 10,172 MPa, 10,805 MPa in the 1/3, 1/2, 2/3, 3/4, 4/5, and 1/1 diameter model, respectively. For torsional load, the maximum stress point in each of the cages was identified at the rod area of the spondylectomy site, with maximum stress of 390.9 MPa (failed at 4459 cycles), 141.35 MPa, 70.098 MPa, and 88.972 MPa, 42.249 MPa, 15.827 MPa, respectively. A cadaveric validation study results were coincided with the finite element model results. Conclusion The most appropriate mesh cage diameter for reconstruction is 1/1 the diameter of the lower endplate of the adjacent cephalad vertebra, due to its ability to withstand both axial and torsional stress. According to the difficulty of large size cage insertion, a cage diameter of more than half of the upper endplate of the caudad vertebrae is acceptable in term of withstand stress. A cage diameter of 1/3 is unacceptable for reconstruction after total en bloc spondylectomy.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3