Accuracy and reproducibility of two-dimensional computed tomography-based positioning of femoral component rotational alignment in preoperative planning for total knee arthroplasty

Author:

Liu Kun,Liu Yuandong,Fan Zongqing,Fu Donglin

Abstract

Abstract Background Poor rotation of the femoral component in total knee arthroplasty (TKA) can result in various postoperative complications, underscoring the critical importance of preoperative planning. Purpose To improve the accuracy of femoral component positioning during TKA, this study compared the accuracy and repeatability of different two-dimensional (2D) computed tomography (CT) measurement methods for measuring the posterior condylar angle (PCA) in preoperative TKA planning. Methods A retrospective analysis was conducted on 75 patients (150 knees) who underwent bilateral lower extremity computed tomography angiography (CTA) at Fuyang People's Hospital from January 2021 to July 2021. Three different methods were used to measure the PCA based on 2D CT images (axial CT slices) and three-dimensional(3D) models (femoral models reconstructed from CT data) in this study. Method 1: Single-plane 2D CT measurement, measuring PCA in the most obvious single-plane CT slice of the surgical transepicondylar axis (sTEA); Method 2: multi-plane 2D CT measurement, identifying and locating anatomical landmarks in multiple 2D CT slices and measuring PCA; Method 3: 3D model measurement, measuring PCA in the reconstructed femur 3D model. Compare the differences in PCA measurements between the three measurement methods. A positive PCA measurement was recorded when the sTEA was externally rotated relative to the posterior condylar line (PCL). Any difference exceeding 3° between the PCA measurement in the 2D CT and the PCA reference value in the 3D model was classified as an outlier. The intraclass correlation coefficient (ICC) and Bland–Altman method were utilized to assess the intra- and inter-observer reproducibility of the three measurement methods. Results The PCA measurement in the single-plane 2D CT was 1.91 ± 1.94°, with a measurement error of − 1.22 ± 1.32° and 12.7% of outlier values. In the multi-plane 2D CT, the PCA measurement was 2.96 ± 1.68°, with a measurement error of -0.15 ± 0.91° and 6.0% of outlier values. The PCA measurement in the 3D model was 3.12 ± 1.69°. The PCA measurement in single-plane 2D CT was notably smaller than that in multi-plane 2D CT and 3D models, with no significant difference between the latter two. The multi-plane 2D CT showed significantly lower measurement error and outlier values than the single-plane 2D CT. All three PCA measurement methods exhibited high reproducibility (ICC: 0.93 ~ 0.97). Conclusions Using of multi-plane 2D CT for measuring PCA in preoperative planning of TKA has high reproducibility and accuracy, with fewer outlier values. We recommend preoperative measurement of PCA using muti-plane 2D CT to improve the accuracy of positioning the femoral component rotational alignment during surgery.

Funder

Natural Science Project of Bengbu Medical College

Project of the Orthopedic of Fuyang People's Hospital, National Clinical Key Specialist

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3