A biomechanical investigation of a novel intramedullary nail used to salvage failed internal fixations in intertrochanteric fractures

Author:

Chen Ping,Fan Zhirong,Xu Nengneng,Wang Haizhou

Abstract

Abstract Purpose The ideal approach for revision surgery following femoral head salvage treatments for an intertrochanteric fracture is still up for debate. A novel variety of proximal femoral bionic intramedullary nail (PFBN) has been created in clinical practice. We aimed to compare the biomechanical results of the novel implant to conventional intramedullary and extramedullary fixation in the treatment of intertrochanteric fracture following primary internal fixation failure. Methods Using finite element analysis, we created a three-dimensional model of the intertrochanteric fracture's helical blade cut-out for this investigation. The PFBN 1 group, the PFBN 2 group, the PFNA group, and the DHS group were our four test groups. For each fracture group, the von Mises stress and displacements of the femur and internal fixation components were measured under 2100 N axial loads. Results The values for the femoral displacement in the PFBN1 group, PFBN2 group, PFNA group, and DHS group were 6.802 mm, 6.716 mm, 8.080 mm, and 8.679 mm, respectively. The internal implant displacement values were 6.201 mm, 6.138 mm, 7.396 mm, and 8.075 mm in the PFBN1 group, PFBN2 group, PFNA group, and DHS group, respectively. The maximum von Mises Stress in the femoral was 187.2 MPa, 85.18 MPa, 106.6 MPa, and 386.2 MPa in the PFBN1 groups, PFBN2 groups, PFNA groups, and DHS groups, respectively. In the PFBN1 groups, PFBN2 groups, PFNA groups, and DHS groups, the maximum von Mises Stress in internal fixation was 586.7 MPa, 559.8 MPa, 370.7 MPa, and 928.4.8 MPa, respectively. Conclusion Our biomechanical research demonstrates that intramedullary fixation is more stable than extramedullary fixation when salvaging failed internal fixations in intertrochanteric fracture. Compared with PFNA and DHS, PFBN showed better biomechanical stability in the treatment of patients with revised intertrochanteric fractures. In light of this, we advocate PFBN fixation as the method of choice for intertrochanteric fracture revision. This result still has to be confirmed in more clinical research.

Funder

National Natural Science Foundation of China

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3