Study of anatomical parameters and intraoperative fluoroscopic techniques for transiliac crest anterograde lag screws fixation of the posterior column of the acetabulum

Author:

Sun Yangyang,Chen Jian,Liu Fanxiao,Chen Zhixue,Li Xiaohui,Lv Fuxin

Abstract

Abstract Background Currently, there is a lack of research investigating the feasibility of employing anterograde lag screw fixation through the iliac crest for minimally invasive percutaneous treatment of the posterior acetabular column, which encompasses retrograde and anterograde screw fixation in posterior acetabular lag screw fixation. And consequently, the purpose of this study was to examine the anatomical parameters of anterograde lag screw fixation of the posterior column of the pelvis through the iliac crest as well as to investigate the intraoperative fluoroscopy technique, to furnish a scientific rationale supporting the practical utilization of this method within clinical settings. Methods In this study, pelvic CT data of 60 healthy adults, including 30 males and 30 females, were accumulated. The mimics 21.0 software was developed to reconstruct the three-dimensional pelvis model, simulate the anterograde lag screw fixation of the posterior column of the acetabulum through use of the iliac crest, and precisely identify the insertion point: Utilizing the widest iliac tubercle as the starting point, the insertion point was moved toward the anterior superior iliac spine by 1.0 cm at a time until it reached 4.0 cm. With a total of five insertion points, all oriented toward the lesser sciatic notch, the initial diameter of the virtual screw measured 5.0 mm, and it was progressively enlarged by 1.0 mm increments until reaching a final diameter of 8.0 mm. Besides, the longest lengths of virtual screws with distinct diameters at divergent entry points were measured and compared. At the same time, the intraoperative fluoroscopy technique for optimal access was analyzed. Results The cross-section from the iliac crest to the lesser sciatic notch was irregular, with multiple curved shapes. Furthermore, the diameter of the screw was determined by the anteroposterior radians and width of the iliac crest plate, while the screw length was determined by the curvature of the square body. On the condition that the screw diameter of the D channel (3.0 cm outward from the widest part of the iliac tubercle to the lesser sciatic notch) was 5 mm, 6 mm as well as 7 mm, the longest screw lengths were (145.6 ± 12.8) mm, (143.6 ± 14.4) mm and (139.9 ± 16.6) mm, correspondingly, indicating statistically substantial distinctions from other channels (P < 0.0001). Intraoperative fluoroscopy demonstrated that the C-arm machine was tilted (60.7 ± 2.9) ° to the iliac at the entrance position and perpendicular to the D-channel at the exit position. Conclusion It is possible to use the new channel to fix the posterior column of the acetabulum with an anterograde lag screw through the iliac crest. In specific, the channel is 3.0 cm outward from the widest part of the iliac tubercle to the lesser sciatic notch. Providing a wide channel, long screw insertion, and high safety, this technique offers a novel approach for minimally invasive treatment of posterior column fractures of the acetabulum.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3