Differences in fixation to young and elderly quadrilateral surfaces with anatomic quadrilateral surface plate (AQSP) based on cortical thickness morphological results

Author:

Guo Jialiang,Dong Weichong,Zhou Yali,Hu Jinglue,Ye Pengyu,Chen Wei,Zhang Yingze,Hou Zhiyong

Abstract

Abstract Aims With relatively thinner cortical thickness, the management of acetabulum osteoporotic fractures in elderly patients is difficult. The aim of the research was to compare and present the morphological characteristics of the quadrilateral plate in young and elderly age groups, such as the area, and position distribution of the thin cortical thickness region, fracture lines maps, and propose a revised design plate for elderly patients based on these anatomic information. Methods As a retrospective research, acetabular fracture with one normal hemipelvises, including 110 men and 39 women, were collected to present the morphological characteristics of the quadrilateral region. The subjects were divided into three different age groups: Group I = 18–40 years (31.3 ± 6.6 years), Group II = 41–60 years (49.9 ± 5.3 years), and Group III ≥ 61 years (68.7 ± 6.8 years). The area of the quadrilateral surface, the area and position distribution of the thin cortical thickness region, the ratio and fracture lines maps were calculated and compared with Mimics in different groups. Results The thin cortical thickness/width region area (TCWRA) was significantly increased in Group III compared with Group I and Group II. The ratio of TCWRA accounted for in the quadrilateral region was also significantly increased in Group III (≥ 61 years) compared with Group I (P = 0.01) and Group II (P = 0.011). None of the subjects had a component involving the “A” zone, thirty-three thin cortical thickness regions were located in the “B” zone, and one hundred and sixteen involved both zones of the quadrilateral plate (“A + B” zone). Furthermore, there were a significant differences in the fracture line distributions in three age groups. More fracture lines of elderly patients were located at anterior part (B zone) compared with Group I and Group II. Conclusions It was identified the area of thin cortical thickness region increased as age grown, and fracture lines were inclined to be more distributed in “B” zone in elderly patients. To meet the demands of acetabular fixation in different age groups, cortical thickness changes in young and elderly individuals should be given special attention when the quadrilateral surface plate is designed. Level of evidence Level IV, observational study.

Funder

National Natural Science Foundation of China

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3