Author:
Li Liang,Li Tian-yan,Jiang Peichao,Lin Guizhen,Wu Hongxiao,Han Xiaochuan,Yu Xuezhong
Abstract
Abstract
Background
The purpose of this meta-analysis was to compare clavicle hook plates versus distal clavicle locking plates for the treatment of Neer type II distal clavicle fractures.
Methods
PubMed (1996 to January 2019), Embase (1980 to January 2019), Web of Science (1990 to January 2019), the Cochrane Library (January 2019), and the China National Knowledge Infrastructure (January 2019) were systematically searched without language restrictions for literature retrieval. The Constant-Murley shoulder joint function score at 3 and 6 months after the operation and the postoperative complications after the operation (shoulder joint pain, abduction restriction, fracture delay healing, subacromial impingement) were the outcomes. Stata 12.0 was used for the meta-analysis.
Results
A total of 9 clinical trials involving 446 patients were finally included in this meta-analysis. The results showed that the improvement in the Constant-Murley shoulder joint function score in the distal locking plate group was better than that in the clavicle hook plate group at 3 and 6 months after the operation (P < 0.05). There were fewer cases of shoulder joint pain and restricted shoulder abduction range of motion in the distal locking plate group, and the difference was statistically significant (P < 0.05). There were no statistically significant differences in fracture delay healing and subacromial impingement between the two groups (P > 0.05).
Conclusion
Compared with the clavicular hook plate, the distal clavicle locking plate for the treatment of Neer type II distal clavicle fractures is associated with better shoulder function recovery and fewer complications related to pain and abduction restriction.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献