A new transpedicular lag screw fixation for treatment of unstable Hangman’s fracture: a minimum 2-year follow-up study

Author:

Liu Yijie,Zhu Yi,Li Xuefeng,Chen Jie,Yang Sen,Yang Huilin,Jiang Weimin

Abstract

Abstract Background A new C2 transpedicular lag screw designed by our team has been used in human cadaver spines for biomechanical testing, and the results showed that the biomechanical properties of the new C2 transpedicular lag screw were better than ordinary screws. The objective of this study is to analyze the clinical efficacy and safety of the new C2 transpedicular lag screw fixation for the treatment of unstable Hangman’s fracture. Methods From March 2013 to June 2017, 25 patients who had unstable Hangman’s fractures were operated on with a new C2 transpedicular lag screw fixation. The patients included 18 males and 7 females whose ages ranged from 31 to 62 years (average 45.4 ± 9.3 years). The cause of the injury was a traffic accident in 17 patients and a fall from height in 8 patients. Other associated lesions included rupture of the spleen (1 patient) and rib fractures (2 patients). According to the Levine-Edwards classification, 17 patients were type II and 8 patients were type IIA, and according to the Frankel Neurological Performance scale, 8 cases and 17 cases were graded as spinal cord injury D and E, respectively. Twenty-three cases received bilateral screw fixation, and 2 cases had unilateral screw fixation because another pedicle was chipped. The whole procedure was accomplished with monitoring by “C”-arm fluoroscopy. Results The mean follow-up time was 36 ± 12 months and ranged from 24 to 60 months. No obvious symptomatic or radiologic postoperative complications were found during the follow-up period. Six cases were restored from D to E while 2 cases remained D according to the American Spinal Injury Association (ASIA) grade. Pre- and postoperative visual analogue scale (VAS) and Neck Disability Index (NDI) were statistically different (P < 0.001). Osseous union was achieved in all cases, and the range of cervical motion recovered to the normal level up to the last follow-up. Conclusions The primary clinical and radiographic efficacies of a new C2 transpedicular lag screw fixation for the treatment of unstable Hangman’s fracture were satisfactory. This approach could be considered a simple, effective, reliable, and economic surgical method for managing unstable Hangman’s fractures.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Reference24 articles.

1. Hadley MN, Dickman CA, Browner CM, Sonntag VK. Acute axis fractures: a review of 229 cases. J Neurosurg. 1989;71:642–7.

2. Roda JM, Castro A, Blázquez MG. Hangman’s fracture with complete dislocation of C-2 on C-3. Case report J Neurosurg. 1984;60:633–5.

3. Schneider RC, Livingston KE, Cave AJ, Hamilton G. Hangman’s fracture of the cervical spine. J Neurosurg. 1965;22:141–54.

4. Leconte P. luxation des deux premieres vertebres cervicales. In: Judet R (ed) Luxation Congenenitale dela Hanche:Fracture du Cou-de-pied Rachis Cervical. Actualites de Chirurgie Orthopedique de 1’Ho pital Raymond-Poincare Masson, Paris. 1964;3:147-166.

5. Judet R, Roy-Camille R, Saillant G. Actuallities de chiirugie orthopedique de 1’hopital Raymound-pointcare: fracture du rachis cervical. Masson, Paris, 1970;8:174-196.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3