Do polyethylene wear particles affect the development of pseudotumor in total hip arthroplasty? A minimum 15-year follow-up

Author:

Ishida Tsunehito,Tateiwa Toshiyuki,Takahashi Yasuhito,Masaoka Toshinori,Shishido Takaaki,Yamamoto Kengo

Abstract

Abstract Background Adverse local tissue reactions have been problematic as an implant-related complication in total hip arthroplasty (THA). Despite the absence of significant metal wear and corrosion, granulomatous pseudotumor has been reported to be caused by polyethylene wear. We performed a long-term follow-up study investigating the relationship between polyethylene wear and pseudotumor formation in THA. Methods This study included 57 patients (64 hips) that underwent primary THA with metal-on-polyethylene or ceramic-on-polyethylene bearing over a minimum follow-up of 15 years. They were stratified into pseudotumor and non-pseudotumor groups and their linear wear rates of polyethylene liner and serum cobalt (Co) and chromium (Cr) ion levels were compared. Pseudotumor was diagnosed on metal artifact reduction sequence-MRI according to its composition and wall thickness using the Hauptfleisch classification. Results The incidence of pseudotumor was 34% (22/64 hips) at the mean follow-up of 16.9 years. Metal ion levels did not differ between the pseudotumor and non-pseudotumor groups, and none of the patients exceeded the Co/Cr ratio of 2.0 μg/L. Moreover, the wear rate in the pseudotumor group was 1.8 times greater than in the non-pseudotumor group (0.14 vs. 0.08 mm/year, P < 0.001). According to an analysis of the receiver operating characteristic curves, the cutoff level of the wear rate to discriminate between pseudotumor and non-pseudotumor patients at 15 years was 0.11 mm/year (area under the curve = 91%; sensitivity = 95%; specificity = 78%; accuracy = 87%). Conclusions Our results might provide new insights into excessive polyethylene wear potentially leading to the future development of both pseudotumor and osteolysis. Further studies are needed to clarify the direct relationship between polyethylene wear and pseudotumor and the mutual effects of osteolysis and pseudotumor in particle reactions.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3