Author:
Tian Rong-hua,Zhang Qin-ming,Chu Feng-long,Li Xiao-yan,Jiang Zhen,Han Liang,Sun Peng,Wang Hai-bin,Chi Yu-lei,Wu Bin
Abstract
Abstract
Background
To compare the efficacy of three-point locating versus routine locating techniques for implanting helical blades for proximal femoral nail anti-rotation-II in the treatment of trochanteric fractures.
Methods
From January 2010 to June 2013, 90 patients with intertrochanteric fractures were surgically treated, including 48 males and 42 females with an average age of 70.5 ± 7.2 years. According to the AO classification, there were 45 cases of A2.1, 35 cases of A2.2, and 10 cases of A2.3. Based on locating techniques, the 90 patients were divided into two groups: the three-point group and the routine group, with 45 patients in each group. All operations were performed by the same group of surgeons using proximal femoral nail anti-rotation (PFNA); the helical blade was inserted into the femoral neck with the three-point locating technique or by the usual method according to treatment group. Several figures including total operation time, elapsed time for implanting the helical blade, intraoperative blood loss, X-ray exposure time, and tip-apex distance (TAD) were measured and compared.
Results
The three-point group was significantly superior as compared to the routine group in terms of total operation time [(59.34 ± 9.42) min vs (67.61 ± 12.63) min, P < 0.01], elapsed time for implanting the helical blade [(4.58 ± 1.25) min vs (7.82 ± 2.19) min, P < 0.01], intraoperative blood loss [(92.78 ± 34.09) ml vs (154.01 ± 39.10) ml, P < 0.01], X-ray exposure time [(8.84 ± 1.45) vs (14.62 ± 2.91), P < 0.01], and tip-apex distance [(16.78 ± 1.55) mm vs (21.91 ± 3.01) mm, P < 0.01]. Among the 90 patients, 80 were followed up for an average time of 12 months (10–15 months), including 42 patients who were part of three-point group and 38 patients who were part of the routine group. No spiral blade cut was found on the femoral head in any patient in the three-point group, whereas it occurred in 2 patients in the routine group 1 month after surgery. However, there was no significant difference in the Harris score between the two groups 6 months after the operation.
Conclusion
The three-point locating method is faster and more accurate than the routine locating method.
Funder
Jining Medical University Helin Academician Fund
Supporting Fund for Teachers' Research at Jining Medical University
Jining Science and Technology Bureau Medical Health Fund
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献