Anterior cervical discectomy and fusion with a zero-profile VA spacer device: a clinical and radiological study with two-year follow-up

Author:

Zhao Hai-Hong,Xu Hao-Wei,Wang Shan-Jin,Hu Tao,Wu De-Sheng

Abstract

Abstract Study design A retrospective study. Objective The aim of this study was to compare clinical and radiological outcomes of the anterior cervical discectomy and fusion (ACDF) with a novel zero-profile variable-angle (Zero-P VA) spacer and a traditional poly-ether-ether-ketone (PEEK) cage and plate system in cases pertaining to cervical radiculopathy/myelopathy. Summary of background data There are two conventional types of ACDF procedures aimed at treating symptomatic cervical spondylosis. The first one involves an uninstrumented “stand-alone” approach utilizing bone graft/cage, while the second incorporates bone graft/cage in conjunction with a front plate positioned before the vertebral bodies. Both procedures have their own inherent advantages and disadvantages. The Zero-P VA spacer, however, represents a unique synthesis by amalgamating the advantages of both traditionally typical procedures. Notably, this spacer can potentially circumvent the issue related to prevertebral soft-tissue disturbance and reduce the occurrence of dysphagia. Methods Using our surgical database, the authors systematically conducted a retrospective analysis encompassing all patients who underwent single-level ACDF between January 2018 and January 2019, with a minimum two-year follow-up. Patients either received a Zero-P VA implant or PEEK cage coupled with plating. The Japanese Orthopedic Association (JOA) score and Visual Analogue Scale (VAS) for arm and neck pain were documented. Dysphagia was evaluated using the Eating Assessment Tool-10 (ETA-10). Additional parameters such as cervical alignment, fusion rate and the incidence of postoperative complications were assessed. Results According to the outcomes of the statistical analysis, there was no substantial disparity that emerged in the advancements observed in the JOA and VAS metrics between the two study cohorts. Noteworthy, however, the ETA-10 scores were statistically significantly reduced in the Zero-P VA group compared to the cage and plating group (p < 0.05). At the final follow-up, there were no statistically significant differences in the height of the operated segment, Cobb angle of the fused segment, C2–C7 Cobb angle and fusion rate between the two groups (p > 0.05). However, postoperative complications were slightly lower in patients with the Zero-P VA group (7.69%) as compared to the cage and plating group (16.67%). Conclusion The clinical outcomes observed with the Zero-P VA spacer used for single-level ACDF were found to be satisfactory. The performance of this device is comparable or even superior to the traditional cage and plating method in preventing postoperative dysphagia and mitigating potential complications associated with the use of a plate.

Funder

Science and Technology Development Fund of Shanghai Pudong New Area

Academic Leaders Program of Health Committee of Pudong New Area

Shanghai East Hospital Xuri Young Excellent Talents Program

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3