Finite element analysis comparison of Type 42A2 fracture fixed with external titanium alloy locking plate and traditional external fixation frame

Author:

Fang Shitao,Zhang Ling,Yang Yunqi,Wang Yun,Guo Jinkun,Mi Lei

Abstract

Abstract Background At present, not all Type AO/OTA 42A2 open fractures can be treated by external fixation brackets, not to mention the inconvenience of this technique in clinical practice. External titanium alloy locking plates, which are lightweight and easy-to-operate, can be used as an alternative treatment option for such patients. However, there are few reports of finite element biomechanical analysis on the titanium alloy locking plates and fixation brackets being placed on the medial side of the tibial fracture. In this study, the biomechanical properties of titanium alloy locking plates and fixation brackets for treating Type AO/OTA 42A2 fractures were compared by applying the finite element method, and the results provided data support for the clinical application of the external titanium alloy locking plate technique. Methods Type AO/OTA 42A2 fracture models were constructed using CT data of a male volunteer for two external fixation techniques, namely the external titanium alloy locking plate technique and the external fixation bracket technique, according to commonly-used clinical protocols. Then, the four-point bending, axial compression, clockwise rotation and counterclockwise rotation tests under the maximum load were simulated in finite element analysis software. The stress distribution, peak stress and overall tibial displacement data for the two different external fixation techniques were obtained and compared. Results In the four different test conditions (i.e., four-point bending, axial compression, clockwise torsion, counterclockwise torsion) under the maximum load, the two external fixation techniques showed obvious von Mises stress concentration at the contacts between the screw and tibia, between the screw and titanium alloy locking plate, between the self-tapping self-drilling needle and tibia, between the self-tapping self-drilling needle and the external fixation device, as well as around the fracture end and around the cortical bone at the upper and lower ends of the tibia. The peak stress was ranged 26.67–558.77 MPa, all below the yield stress strength of titanium alloy. The peak tibial displacement of the external titanium alloy locking plate model was smaller than that of the fixation bracket model. In terms of structural stability, the external titanium alloy locking plate technique was superior to the external fixation bracket technique. Conclusions When fixing Type AO/OTA 42A2 fractures, external titanium alloy locking plates are not only lightweight and easy-to-operate, but also have better performance in terms of axial compression, bending and torsion resistance. According to the finite element biomechanical analysis, external titanium alloy locking plates are superior to traditional external fixation brackets in treating Type AO/OTA 42A2 fractures and can better meet the needs of clinical application.

Funder

Hunan Provincial Health and Family Planning Commission Scientific Research Fund

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3