Color Doppler ultrasonography of an agitated solution is predictive of accurate catheter placement for a continuous popliteal sciatic nerve block

Author:

Bowens Clifford,Badiola Ignacio J.ORCID,Allen Brian Frazer Scott,Canlas Christopher Loredo,Gupta Rajnish Kumar,Jaeger Lisa Michelle,Briggs Eric Russell,Corey John Matthew,Shi Yaping,Schildcrout Jonathan Scott,Malchow Randall John

Abstract

Abstract Background Continuous peripheral nerve catheters (PNCs) have been shown to provide superior postoperative analgesia, decrease opioid consumption, and improve patient satisfaction compared with single injection techniques. In order to achieve success and reliability, accurate catheter positioning is an essential element of PNC placement. An agitated solution of normal saline, D5W, or a local anesthetic solution can be produced by the introduction of air to the injectate, creating air bubbles that can enhance ultrasonographic visualization and possibly improve block success. Methods Eighty-three patients were enrolled. Ultrasound-guided continuous popliteal sciatic nerve blocks were performed by positioning the tip of a Tuohy needle between the tibial and common peroneal branches of the sciatic nerve and threading a catheter. An agitated local anesthetic solution was injected through the catheter, viewed with color Doppler ultrasound and video recorded. A peripheral block score (lower score = greater blockade, range 0-14) was calculated based upon the motor and sensory testing at 10, 20, and 30 min after block completion. The color Doppler agitation coverage pattern for the branches of the sciatic nerve was graded as follows: complete (> 50%), partial (> 0%, ≤ 50%), or none (0%). Results The degree of nerve blockade at 30 min as judged by median (10th, 90th percentile) peripheral block score was significant for partial or complete color Doppler coverage of the sciatic nerve injectate compared to no coverage [3 (0, 7) vs 8 (4, 14); p < 0.01] and block onset was faster (p = 0.03). The block success was higher in groups with partial or complete coverage of the branches of the sciatic nerve vs no coverage (96% vs 70%; p = 0.02). Conclusions Injection of an agitated solution through a popliteal sciatic perineural catheter is predictive of accurate catheter placement when partial or complete coverage of the sciatic nerve branches is visualized with color Doppler ultrasound. Trial registration NCT01591603

Publisher

Springer Science and Business Media LLC

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3