High-flow nasal oxygen vs. standard oxygen therapy for patients undergoing transcatheter aortic valve replacement with conscious sedation: a randomised controlled trial

Author:

Scheuermann S.,Tan A.ORCID,Govender P.,Mckie M.,Pack J.,Martinez G.,Falter F.,George S.,A. Klein A.

Abstract

Abstract Background Minimally invasive surgery is becoming more common and transfemoral transcatheter aortic valve replacement is offered to older patients with multiple comorbidities. Sternotomy is not required but patients must lie flat and still for up to 2–3 h. This procedure is increasingly being performed under conscious sedation with supplementary oxygen, but hypoxia and agitation are commonly observed. Methods In this randomised controlled trial, we hypothesised that high-flow nasal oxygen would provide superior oxygenation as compared with our standard practice, 2 l min−1 oxygen by dry nasal specs. This was administered using the Optiflow THRIVE Nasal High Flow delivery system (Fisher and Paykel, Auckland, New Zealand) at a flow rate of 50 l min−1 and FiO2 0.3. The primary endpoint was the change in arterial partial pressure of oxygen (pO2) during the procedure. Secondary outcomes included the incidence of oxygen desaturation, airway interventions, the number of times the patient reached for the oxygen delivery device, incidence of cerebral desaturation, peri-operative oxygen therapy duration, hospital length of stay and patient satisfaction scores. Results A total of 72 patients were recruited. There was no difference in change in pO2 from baseline using high-flow compared with standard oxygen therapy: median [IQR] increase from 12.10 (10.05–15.22 [7.2–29.8]) to 13.69 (10.85–18.38 [8.5–32.3]) kPa vs. decrease from 15.45 (12.17–19.33 [9.2–22.8]) to 14.20 (11.80–19.40 [9.7–35.1]) kPa, respectively. The percentage change in pO2 after 30 min was also not significantly different between the two groups (p = 0.171). There was a lower incidence of oxygen desaturation in the high-flow group (p = 0.027). Patients in the high-flow group assigned a significantly higher comfort score to their treatment (p ≤ 0.001). Conclusion This study has demonstrated that high flow, compared with standard oxygen therapy, does not improve arterial oxygenation over the course of the procedure. There are suggestions that it may improve the secondary outcomes studied. Trial registration International Standard Randomised Controlled Trial Number (ISRCTN) 13,804,861. Registered on 15 April 2019. https://doi.org/10.1186/ISRCTN13804861

Funder

Fisher and Paykal Healthcare

Publisher

Springer Science and Business Media LLC

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3