Stability of sensor-based gait parameters reassessed after a period of one year in people with multiple sclerosis

Author:

Müller Roy,Hamacher Daniel,Keune Philipp M.,Oschmann Patrick

Abstract

Abstract Background Currently, there are several studies showing that wearable inertial sensors are highly sensitive in the detection of gait disturbances in people with multiple sclerosis (PwMS), showing excellent reliability within one or 7–14 days. However, it is not known how stable these gait parameters remain over a longer period of time. This is surprising, because many treatments last longer than two weeks. Thus, the purpose of the current study was to examine gait parameters obtained by means of wearable inertial sensors during a 6-min walk and to reassess these parameters after a period of one year. Methods Fifty PwMS (without a relapse or a recent change in the Expanded Disability Status Scale (EDSS) or treatment) and 20 healthy participants were examined at two assessment points (interval between assessments: 14.4 ± 6.6 months). At each assessment point, all participants had to complete a 6-min walking test, an observer-rater test (Berg Balance Scale, BBS) and a Timed-up and Go Test (TUG). To measure mean gait parameters (i.e. walking speed, stride length, stride time, the duration of the stance and swing phase and minimum toe-to-floor distance), as well as the intraindividual standard deviation of each mean gait parameter, wearable inertial sensors were utilized. Results We found that even after one year all mean gait parameters showed excellent Intraclass Correlation Coefficients (ICC between 0.75 and 0.95) in PwMS. Looking at MS subgroups, the ICCs were slightly higher in MS subgroup 2 (EDSS 2.0–5.0) than those in MS subgroup 1 (EDSS 0.0–1.5) and healthy controls. Compared to the mean gait parameters, parameters of gait variability showed only good-to-fair ICC values in PwMS. Concerning BBS and TUG, the ICC values after one year were close to the ICC values of the measured mean gait parameters. Conclusions Due to the excellent stability of mean gait parameters after one year, these sensor-based gait parameters can be identified as clinically relevant markers to evaluate treatment effects over a longer (several months) period of time in MS.

Publisher

Springer Science and Business Media LLC

Subject

Neurology (clinical),General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3